3. Handling and use 

 

Before use 

 

Make yourself familiar with all operation elements of your applicator before you attempt 
to test the applicator and go into practice.  

 

TeleDart

 

®

 RD206 can be constructed for right- and lefthanded users, which allows to 

order your applicator according to your individual requirements.  

 

Before shipment, all TeleDart

 

®

 applicators are tested at a distance of 15m (16

 

yds)  

using a 

TeleDart

 

®

 Dart Syringe 3cc

 

For your training we recommed to fill the dart with water and to use a training needle 
TN1530. In that case it is not necessary to pressurize the dart syringe. If you have to 
work  with  other  dart  volumes,  please  proceed  in  the  same  way.  In  order  to  always 
guarantee the best ballistics, the syringe dart has to be filled completely. Note down all 
pressure values and make your individual pressure table. 

 

Assembling 

 

  Safety 

 

Check if the trigger safety is pushed in. The red ring must not be visible. 

 

  Inserting of the CO2-cartridge 

 

Unscrew the cartridge holder and insert a CO2-cartridge. Tighten up the cartridge 
holder until the cartridge is tapped. 

      

 

      

Only replace open cartridges if they are completely empty. Further all safety  

      advices marked on the packing of the CO2-cartridges are valid. TeleDart

 

®

 does  

      not assume any  liability for damages and injuries caused by improper handling  
      of CO2-cartridges. 

 

  Connecting the foot-airpump 

 

The lateral tube connection is located on the lower part of the pistol grip. Latch the 
hose of the foot-airpump with the hose connector. To unlatch the foot-airpump the 
locking sleeve of the hose connector has to be pushed back until the hose unlatches. 

 

  Pressurizing 

 

The applicator is pressurized if you push the pressure regulation knob down.

 

Observe 

the gauge and release the knob when you have reached the desired pressure. 

 

 

In case you have built up too much pressure, you can correct that easily. Just push the 
pressure release valve until you have reached the desired pressure. 

 

When pressurizing with the air pump, the air pump must be reconnected to build up 
pressure after each shot. 

 

The TeleDart

 

®

 RD206 has a safety valve, which opens automatically if you 

exceed the allowed maximum pressure of 10 bar (Version RD206-D at 6 bar). 

 

The safety  valve is engineered to protect your applicator from damages caused  
by dangerous overpressure >

 

10

 

bar (> 6 bar RD206-D). The exceeding of     the 

particular  maximum  pressure  into  the  red  marked  area  of  the  manometer  can 
cause damages to your applicator. Damages to material, which are proven to be 
caused by deliberate exceeding of the maximum pressure cease our guarantee! 

 

      

We want to point out that a verifiable manipulation of the safety valve immediately   

    

  

ceases our guarantee and in this case we do not assume any liabilityfor damages  

    

  

to persons or material. 

 
 
 

Summary of Contents for RD206

Page 1: ...Then you will be sure to do your remote injections safely and without problems Successful working The Team of TeleDart Pressure table for the TeleDart applicator RD206 RD206 D Dear customer Thank you for having chosen a TeleDart applicator This applicator has been tested in a closed area Please note that this is only a guideline which may differ from your own shooting results as wind and weather c...

Page 2: ... to 5 ccs Calibre 13 5 ccs to 20 ccs Calibre 16 1 ccs to 20 ccs Short barrel Available Optimal range with standard barrel calibre 11mm 1 m 30 m depending on dart size Standard sight Backsight front sight Pressure build up CO2 cartridge 16 g 45 g Airpump Pressure control RD206 Continuous 0 10 bar Pressure control RD206 D Continuous 0 6 bar Safety striker Yes pin retainer Safety valve Yes Pressure r...

Page 3: ...are empty or damaged Avoid that children and other unauthorized individuals enter into possession of darts or part of darts Clean darts and part of darts contamined with drugs before disposing them Never use drugs or alcohol while handling this product Never use our applicators with pure oxygen e g oxygen cartridges Of course all regulations applicable in your country with regard of the handling o...

Page 4: ...ume any liability for damages and injuries caused by improper handling of CO2 cartridges Connecting the foot airpump The lateral tube connection is located on the lower part of the pistol grip Latch the hose of the foot airpump with the hose connector To unlatch the foot airpump the locking sleeve of the hose connector has to be pushed back until the hose unlatches Pressurizing The applicator is p...

Page 5: ... cleaned with a moist cloth Never use chemical cleansers or oil Regularely check if there is dirt inside the barrel If necessary brush it dry with the cleaning brush comes with the barrel Don t use chemical cleansers or oil Further care is not necessary 5 Maintenance Special maintenance is not necessary If your barrel becomes difficult to fix grease the o rings of the barrel retainer 6 Storage For...

Page 6: ...rantee claim will not be accepted for damages which are irrelevant for the value or the use of the applicator which are caused by irregular environmental conditions unprofessional use or use which is not in accordance with regulations If the points in the user and maintenance manual are not observed a guarantee claim will not be accepted 8 Should the applicator be used in another country than the ...

Reviews: