background image

TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany 

  

 

 

Seite 2 

27.06.2019 

 

 

 

 

 
 

 

 

Technical data: 

 

 

Weight 

Approx. 1,2 kg 

Overall length  

with barrel 

Material 

90 cm 
Aluminium

 

 

Barrels /  
Syringe volumes 

Plug-on barrel system with adapter 
 
Calibre 11   (1 ccs to   5 ccs) 
Calibre 13   (5 ccs to 20 ccs) 
Calibre 16   (1 ccs to 20 ccs) 
 

Short barrel 

Available 

Optimal range 

with standard barrel calibre 11mm 

1 m – 30 m 
(depending on dart size) 

Standard sight 

Backsight / front sight 

Pressure build-up 

CO2 cartridge (16 g/45 g) / Airpump 

Pressure control RD206 

Continuous (0 – 10 bar) 

Pressure control RD206-D 

Continuous (0-6 bar) 

Safety striker 

Yes (pin retainer) 

Safety valve 

Yes 

Pressure relief valve 

Yes 

Kinetic energy 

> 7.5 joules 

 

Summary of Contents for RD206

Page 1: ...Then you will be sure to do your remote injections safely and without problems Successful working The Team of TeleDart Pressure table for the TeleDart applicator RD206 RD206 D Dear customer Thank you for having chosen a TeleDart applicator This applicator has been tested in a closed area Please note that this is only a guideline which may differ from your own shooting results as wind and weather c...

Page 2: ... to 5 ccs Calibre 13 5 ccs to 20 ccs Calibre 16 1 ccs to 20 ccs Short barrel Available Optimal range with standard barrel calibre 11mm 1 m 30 m depending on dart size Standard sight Backsight front sight Pressure build up CO2 cartridge 16 g 45 g Airpump Pressure control RD206 Continuous 0 10 bar Pressure control RD206 D Continuous 0 6 bar Safety striker Yes pin retainer Safety valve Yes Pressure r...

Page 3: ...are empty or damaged Avoid that children and other unauthorized individuals enter into possession of darts or part of darts Clean darts and part of darts contamined with drugs before disposing them Never use drugs or alcohol while handling this product Never use our applicators with pure oxygen e g oxygen cartridges Of course all regulations applicable in your country with regard of the handling o...

Page 4: ...ume any liability for damages and injuries caused by improper handling of CO2 cartridges Connecting the foot airpump The lateral tube connection is located on the lower part of the pistol grip Latch the hose of the foot airpump with the hose connector To unlatch the foot airpump the locking sleeve of the hose connector has to be pushed back until the hose unlatches Pressurizing The applicator is p...

Page 5: ... cleaned with a moist cloth Never use chemical cleansers or oil Regularely check if there is dirt inside the barrel If necessary brush it dry with the cleaning brush comes with the barrel Don t use chemical cleansers or oil Further care is not necessary 5 Maintenance Special maintenance is not necessary If your barrel becomes difficult to fix grease the o rings of the barrel retainer 6 Storage For...

Page 6: ...rantee claim will not be accepted for damages which are irrelevant for the value or the use of the applicator which are caused by irregular environmental conditions unprofessional use or use which is not in accordance with regulations If the points in the user and maintenance manual are not observed a guarantee claim will not be accepted 8 Should the applicator be used in another country than the ...

Reviews: