![Telecom Behnke 20-0001B-IP Series Instructions Manual Download Page 66](http://html.mh-extra.com/html/telecom-behnke/20-0001b-ip-series/20-0001b-ip-series_instructions-manual_1079985066.webp)
66
www.behnke-online.de
GB
Specifications
Instructions for Behnke 20-0001B-IP, 20-0014B-IP, 20-0016B-IP
alarm input or, in the case of a detached intercom station, via the
sabotage contact of the door module
Safety shutdown in case of sabotage: Disabling the network
of the extension port
Radar sensor: available when connecting a radar sensor extension module
Triggering: for arriving and/or departing
persons/objects
maximum detection range: 1-100 % (approx. 10 m)
Detection pause: 1-25 s
Radar sensor relay: Normally open or normally closed contact with an
activation time of 1-255 s
Schedule: Execute calls or commands at a specific time
Triggering: at the beginning and/or at the end of a valid time period
of the schedule
Acoustics
Noise detection: switchable: Measuring and evaluating ambient noise
Volume: 0-100 %
automatic increase of volume in noisy environment: off
or from a certain volume class (1-5)
Audio amplifier: 1 W output power
Microphone sensitivity: 0-100 %
Analogue audio: Transmitting/reception sensitivity: 50-150 %
Transmitting/reception gain: -10-10 dB
automatic sensitivity adjustment
Echo barrier
Echo cancellation
automatic gain control for microphone