4 - Radio codes deletion
4.1 - Single radio code
1. Press 11 times* P1 and hold the last time. The buzzer emits an intermittent sound.
2. Press the button of the transmitter relative to the code to be deleted.
Successful deletion is indicated by the continuous sound of the buzzer.
4.2 - All the radio codes
1. Press 12 times* P1 and hold the last time for 10 seconds. The buzzer emits a fast intermittent sound.
2. Release when the sound becomes continuous.
5 - Remote memorization/deletion of radio codes
5.1 - Remote memorization of other radio codes
(The added radio code will have the same functions as the code used for memorization.
This procedure is compatible with any type of transmitter.).
5.2 - Remote deletion of a radio code
1. Press the button P3** of the memorized transmitter 3 times and hold. The
buzzer emits a slow intermittent sound.
2. Press a button relative to the code to be deleted within 5 seconds.
Successful deletion is indicated by the continuous sound of the buzzer.
** The button P3 is located inside the transmitter.
memorized
memorized
memorized
new
1. Press the button P3** of the memorized transmitter
and hold it. The buzzer emits a continuous sound.
2. Press a button relative to an already memorized
code. The buzzer stops for 1 second and then starts
the continuous sound again.
3. Press the button relative to the new code to be
memorized.
Successful memorization is indicated by the
intermittent sound of the buzzer.
EN
TECHNICAL SPECIFICATIONS
* The buzzer will make a beep each press.
Power supply
110-230V~ 9.1-13.1A
50-60Hz
Max. commutable power at the relay
3000W (cosφ=1) @ 230V~
1000W (cosφ=1) @ 110V~
Only for 110-230V~ loads
Max. inrush current for the output
80A (20ms)
Operating temperature range
-20° - +40°C
Protection rating
IPX0
Reception frequency
868.3 MHz (TVRRL868Gx)
916 MHz (TVRRL916Gx)
Radio memory capability (transmitters)
42
x 3
...
P3
< 5 s
1 s
...
P3
< 5 s
< 5 s