8
The temperature sensor (NTC 10K/3435K) activates whenever there is danger of ice forming.
TEMPERATURE sensor
1.1
4.3
Factory setting
DEACTIVATED
TEM
PERATURE
Alarm priority
MEDIUM
ALARM ACTIVATED when
What happens with ALARM ACTIVATED
ALARM NOT ACTIVE when
The measured temperature is below 2 °C
and the slats are closed.
The control unit tilts the pergola slats to
10%
of full opening.
The measured temperature is above 3 °C or
the slats are open.
t
°
L2
Activation/deactivation of the TEMPERATURE sensor by means of the transmitter *
Deactivation
Press the “
STOP
” button of a memorized 7/42
or 3-channel transmitter
10 times
and hold the
last time for
2 s.
The buzzer emits
2 beeps
.
L4
flashes once every
3 seconds
.
Activation (only if the sensor is connected)
Press the “
STOP
” button of a memorized 7/42
or 3-channel transmitter
10 times
and hold the
last time for
2 s.
The buzzer emits a continuous
sound for
4 seconds
.
STOP
L4 flashes
once every 3 s
(10x)
continuous
sound 4 s
STOP
(10x)
***
***
* The motors must be stopped. ** The buzzer will make a beep each time the button is pressed. ***
The motors make short movements
P1
( 5 s)
continuous
sound
4 s
L4 flashes
once every 3 s
Activation/deactivation of the TEMPERATURE sensor by means of P1 *
ACTIVATION ***
(only if the sensor is connected)
DEACTIVATION ***
**
5x