background image

2

INDEX

1   Connections, adjustments and control unit warnings

 -------------------- 

page 3

2   TRANSMITTERS   

--------------------------------------------------------------------- 

pages 4 - 5

2.1 Memorization of 7-ch transmitter

2.2 Deletion of 7-ch transmitter

2.3 Remote memorization

2.4 Remote deletion

3   MOTOR CONFIGURATION 

----------------------------------------------------------- 

pages 5 - 6

4   SENSORS  

------------------------------------------------------------------------------- 

pages 7 - 9

4.1 WIND sensor

4.2 SNOW condition

4.3 TEMPERATURE sensor

4.4 RAIN sensor

4.5 Modification of the alarm automatic angles 

5   FURTHER DETAILS 

 

----------------------------------------------------------- 

page 10

5.1 Troubleshooting (what to do IF...) 

5.2 Replacing the control unit

6   Technical specifications  

----------------------------------------------------------- 

page 11

WARNINGS

 

The product at issue must be installed, commissioned and maintained only by licensed and authorised people, respecting the laws concerning 

the automatic covers. All the connections must be rated for a single-phase 230V~ power supply. For the disconnection from the power line, use 

an all-pole switch with contacts having a dimension of at least 3,5mm. Only suitable materials for the connections must be used to guarantee 

insulation that complies with current standards on the subject of electrical safety. The receiver only carries out movement commands and all safety 

devices required by the system must be arranged separately. Before the connection to the power supply make sure that the sensors and motors are 

correctly connected. A faulty connection of the motors (polarity inversion) could damage them together with the connected mechanical elements. 

PRODUCT DISPOSAL: at the end of this product’s useful life, it must not be disposed of as domestic waste, but must be taken to a collection 

centre for waste electrical and electronic equipment. To prevent infiltration of water, wire the product as follows:

The manufacturer, Teleco Automation s.r.l, declares that the type of radio equipment is compliant with Directive 2014/53 / EU. The full text of the EU 

compliance declaration is available at the following Internet address: www.telecoautomation.com/ceIn the view of a constant development of their 

products, the manufacturer reserves the right for changing technical data and features without prior notice.  

INFORMATION TO USERS 

under art. 

14 of the 2012/19/EU DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of 4 July 2012 on waste electrical and electronic equipment 

(WEEE). The crossed bin symbol on the equipment, or its packaging, indicates that the product must be collected separately from other waste 

at the end of its useful life and not with mixed urban waste. Please contact your municipality, or local authority, for all information regarding 

the waste sorting systems available in the area. The retailer is obliged to collect the old equipment free-of-charge when the customer buys a 

new equivalent equipment. This is to encourage correct recycling/disposal. Appropriate waste sorting for the subsequent recycling,reatment and 

disposal in an environmentally sound way of the disused equipment avoids negative effects on the environment or human health and favours the 

re-use or recycling of the equipment’s materials.

Summary of Contents for TVPLR868AC2

Page 1: ...Hz TVPLR916AC2B h 50mm 916MHz MOTOR 1 to adjust the angle It is possible only when the louvre is totally extended the closing limit switch of motor 2 is reached MOTOR 2 to pack the louvres It is possi...

Page 2: ...PRODUCT DISPOSAL at the end of this product s useful life it must not be disposed of as domestic waste but must be taken to a collection centre for waste electrical and electronic equipment To prevent...

Page 3: ...Earth wires GND M2 230Vac M2 M1 M1M2GND LED COLOUR STATUS MEANING L1 RED ON Power ON L2 RED Two quick flashes every 10 s Rain alarm par 4 4 Three quick flashes every 10 s Ice Snow alarm par 4 2 4 3 Fo...

Page 4: ...P1 or P2 and hold The buzzer emits an intermittent sound Press the button of the transmitter to delete within 10 seconds Successful deletion is indicated by a continuous sound of the buzzer The buzzer...

Page 5: ...sound Memorized x 3 P3 5 s intermittent sound To be deleted Memorized Note The button P3 is located inside the transmitter Press the button P3 of the memorized transmitter 3 times and hold The buzzer...

Page 6: ...tor Extend totally the louvres and set the second limit switch of M2 motor CH1 CH2 CH3 CH4 CH5 CH6 CH7 M1 OPEN M1 CLOSE M1 OPEN M1 CLOSE OPEN CLOSE Closed totally the louvres and set the first limit s...

Page 7: ...GH DIP1 DIP2 DIP3 Km h OFF OFF OFF 40 OFF OFF ON 45 OFF ON OFF 50 OFF ON ON 55 ON OFF OFF 60 ON OFF ON 65 ON ON OFF 70 ON ON ON 75 To manage the alarm associated with snow the temperature and the rain...

Page 8: ...ation Press the STOP button of a memorized 7 42 or 3 channel transmitter 10 times and hold the last time for 2 s The buzzer emits 2 beeps L4 flashes once every 3 seconds Activation only if the sensor...

Page 9: ...n of a memorized 7 42 or 3 channel transmitter for 10 s The buzzer emits a continuous sound for 4 seconds STOP L2 flashes once every 2 s 10 s continuous sound 4 s STOP 10 s Change of the automatic ala...

Page 10: ...time There s no continuous beep during transmitter memorization There must be no more than 1 second between pressing the buttons It is impossible to memorize a transmitter The radio code is already m...

Page 11: ...16 Rain sensor power supply 12 Vdc max 100mA Anemometer 4 pulses rotation ANEM4 Temperature probe NTC R 10Kohm B 3435K Protection rating IP54 Material of the box and its cover Not suitable for direct...

Page 12: ...per output LED CARD to control the 1 colour RGB or RGBW 12 24Vdc LED lights optional only in TVPLRxxxAC2 version TMP150 TEMPERATURE sensor TELECO AUTOMATION S R L ITALY Tel 39 0438 388511 info teleco...

Page 13: ...le solo quando l estensione del motore 2 massima MOTORE 2 impacchettamento dei profili possibile solo quando l angolazione del motore 1 massima TELECO AUTOMATION SRL Via dell Artigianato 16 31014 Coll...

Page 14: ...O DEL PRODOTTO alla fine della vita utile l apparecchio non deve essere smaltito come rifiuto domestico ma conferito in un centro di raccolta rifiuti elettrici ed elettronici Per evitare infiltrazioni...

Page 15: ...Finecorsa di sicurezza Un lampeggio ogni 2 s Sensore pioggia disattivato Un lampeggio ogni 3 s Sensore temperatura disattivato L3 BLU Un lampeggio ogni 2 s Modalit di configurazione Allarmi sensori cl...

Page 16: ...re 7 canali 1 1 2 2 P1 o P2 Premere 3 volte il tasto P1 o P2 e tenere premuto Il buzzer emette un suono intermittente Premere un tasto del trasmettitore da cancellare entro 10 secondi All avvenuta can...

Page 17: ...zione remota 2 4 Cancellazione remota x 3 P3 5 s suono intermittente Da cancellare Memorizzato Nota Il tasto P3 si trova all interno del trasmettitore Premere 3 volte il tasto P3 del trasmettitore gi...

Page 18: ...completamente i profili ed impostare il 2 finecorsa del motore M2 CH1 CH2 CH3 CH4 CH5 CH6 CH7 M1 APRE M1 CHIUDE M1 APRE M1 CHIUDE APRE CHIUDE Chiudere completamente i profili ed impostare il 1 finecor...

Page 19: ...50 OFF ON ON 55 ON OFF OFF 60 ON OFF ON 65 ON ON OFF 70 ON ON ON 75 L2 VENTO Priorit allarme ALTA Per poter gestire l allarme associato alla condizione di neve necessario combinare il sensore di temp...

Page 20: ...zione disattivazione sensore TEMPERATURA con P1 ATTIVAZIONE solo se il sensore collegato DISATTIVAZIONE 5x Attivazione disattivazione sensore TEMPERATURA con il trasmettitore memorizzato Attivazione s...

Page 21: ...o suono continuo 3 s suono continuo P1 o P2 ALLARME PRESENTE quando Cosa fa quando ALLARME PRESENTE ALLARME NON PRESENTE quando La superficie sensibile del sensore rileva gocce d acqua La centrale ori...

Page 22: ...assare pi di 1 secondo Non si sente il bip continuo durante la memorizzazione di un trasmettitore Fra la pressione di un tasto e quella successiva non deve passare pi di 1 secondo Non possibile memori...

Page 23: ...ori 16 Alimentazione sensore pioggia 12 Vdc max 100mA Anemometro 4 impulsi giro ANEM4 Sonda temperatura NTC R 10Kohm B 3435K Grado di protezione IP54 Materiale scatola e coperchio non adatto all espos...

Page 24: ...5A per uscita LED CARD per il controllo di luci LED 12 24Vdc 1 colore RGB o RGBW opzionale solo nella versione TVPLRxxxAC2 RAIN102x Sensore PIOGGIA TMP150 Sonda di TEMPERATURA TELECO AUTOMATION S R L...

Reviews: