Problem
Solution
At power-on, the control unit does not move the motors and emits no warning.
The system needs to be programmed, see section
2
.
L3
flashes and an intermittent sound starts after configuration.
Repeat the procedure. At the end of it
DO NOT
change the
DIP4-5
setting.
The configuration procedure does not start upon pressing
P1
and
P2
twice.
P1
and
P2
must be pressed simultaneously. There must be no more than 1 second
between pressing the first and the second time.
There’s no continuous beep during transmitter memorization.
There must be no more than 1 second between pressing the buttons.
It is impossible to memorize a transmitter.
The radio code is already memorized or the memory is full.
5.1
TROUBLESHOOTING (what to do IF…)
In the event of a defective control unit, provided the memory (see below) is still
working, it may be replaced without losing the configuration parameters.
To do this, the control unit must not be powered:
• insert the memory card of the defective control unit into the new one;
• set the DIP switches of the new control unit as they were in the old one;
• switch the system on.
5.2
Replacing the control unit
5.3
Quick learning of limit switch
If the following have been already programmed
• motor control mode
• the correct motor direction
• at least one transmitter for each of the independent motor output
• current threshold to be applied
it is possible to carry out the SELF-LEARNING OF LIMIT SWITCHES
without
accessing the control unit
.
•
Pergola with 2 synchronized motors:
Together
MOTOR 1
and
MOTOR 2
•
Pergola with 2 independent motors:
MOTOR 1
first, then
MOTOR 2
Test the movement and the direction of the motors by
means of the memorized transmitter, after this keep the
button
P3
of the transmitter pressed for
10 s
.
Memorized
P3
( 10 s)
M1
M2
230Vac
M2
M1
12/24Vdc
LED
Temp.
Memory
complete
closing
complete
opening
...
...