![Teleco TVNRG868E04 Installer Instruction Manual Download Page 5](http://html1.mh-extra.com/html/teleco/tvnrg868e04/tvnrg868e04_installer-instruction-manual_1079794005.webp)
5
#
CONNECTION
1
Motor Earth
2
240V
ac
Power supply - Earth
3
240V
ac
Power supply IN - LIVE
4
240V
ac
Power supply IN - NEUTRAL
5
Motor - OPEN
6
Motor - COMMON
7
Motor - CLOSE
8
240Vac LIGHT OUTPUT
(300W max. lamp)
9
ELECTRICAL CONNECTIONS
2.3
High voltage terminals
MOTOR
240Vac
Line IN
EARTH
Via dell'Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
Tel. +39.0438.388511 Fax +39.0438.388536
Web site: www.telecoautomation.com
DATE: 02/03/17
REV: 1.0
ETI-MORS-RDSB02
Da stampare a colori
L N
Low voltage terminals
Wired
infrared/8K2
safety edge
Emergency
STOP (TB)
Push-
button
(TD)
Wired
photocells
TB
COM
COM
TD
Via dell'Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
Tel. +39.0438.388511 Fax +39.0438.388536
Web site: www.telecoautomation.com
DATE: 02/03/17
REV: 1.0
ETI-MORS-RDSB02
Da stampare a colori
#
CONNECTION
12
Photocells power supply (+12Vdc)
13
Safety common (COM)
14
Photocells power supply (0Vdc)
15
N.C. contact FTC (photocells)
16
Infrared/8K2 safety edge input (brown)
17
Infrared/8K2 safety edge input (green)
18
Infrared/8K2 safety edge input (white)
19
Push-button common (COM)
20
Push-button (step-by-step, N.O.)
21
Emergency STOP push-button (N.C.)
22
Emergency STOP push-button common
see par.2.3 for
connections