![Teleco TVNRG868E04 Installer Instruction Manual Download Page 2](http://html1.mh-extra.com/html/teleco/tvnrg868e04/tvnrg868e04_installer-instruction-manual_1079794002.webp)
2
PRODUCT DESCRIPTION
1
TVNRG868E04
Control unit with integrated radio receiver for the remote control of tubular motors up to 450W, with built-in limit switch, for rolling shutters and rolling doors.
FEATURES
- Compact plastic case with easy fixing
- Front cover with buttons for up/stop/down commands and
LED for alarms status
- Integrated LED courtesy light
- Wireless control via radio transmitters
- Wireless safety edge with auto-test
- Bidirectional communication: door status is shown by the
transmitter LED with different colour
- Alarm function, in combination with shock sensor (TVSSH868A01 and
BST25S) and integrated speaker
W
irele
ss system easy to c
on
ne
ct
Wire
less safety syst
em
Fro
nt c
over
with up/stop/do
wn
bu
tto
ns
Op
tio
na
l ala
rm buzzer to be f tte
d i
n t
he
c
as
e
CONNECTIONS & FUNCTIONING
- Wired inputs for safety edge (both resistive 8K2 and infrared)
- Wired inputs for command push-button and emergency STOP push-button
- Possibility to connect an external 240Vac courtesy light
- 2 Functioning modes: semi-automatic (automatic o hold-to-run
closing) and automatic
- Automatic closing with programmable pause time
- Exclusion of the safety edge in the last part of the closure, in case of bumpy
floor
- Motor torque control
- “Holiday mode” to lock the control unit with the front cover
INDEX
1. Product description ----------------------------------------------------------------page 2
2. Installation
-----------------------------------------------------pages 3 - 8
2.1 Mounting the product
2.2 Control Unit diagram
2.3 Electrical connections
2.4 Wired safety device connections
2.5 Mounting the wireless “shock” safety system (BST26)
3. Preliminary check and initial start-up ---------------------------------------------pages 9 - 10
3.1 Limit switch configuration and direction check
3.2 Matching of the wireless safety device system & Activation/Deactivation
3.3 Functioning mode
3.4 Exclusion of safety edge
4. Transmitters & memorization -----------------------------------------------------pages 12 - 15
4.1 Radio codes memorization
4.2 Single channel: door status request (ask)
4.3 Alarm function: shock sensor memorization
4.4 Remote memorization of the first transmitter
4.5 Remote memorization of further transmitters
5. Transmitters deletion --------------------------------------page 16
5.1 Remote deletion of a transmitter
6. Time setting ----------------------------------------------------------------page 17
6.1 Auto close time setting
6.2 Courtesy light time setting
7. Other programming --------------------------------------------------------page 18
7.1 Motor torque control
7.2 “Holiday mode”
8. Troubleshooting --------------------------------------------------------page 19