If the door reopens having hit the floor the safety edge exclusion should be set to ‘turn off’ the edge 50mm before it hits the floor.
1. Power on & within 30 seconds L1 & L2 lights are on for 5 Seconds & then L1 & L2 lights turn off.
2. Within 5 seconds of step 1 press & hold P1 & P2 once for 1 second – L1 & L2 lights will flash
rapidly.
3. Press P2 button 10 times and keep it pressed on the 10
th
press for 5 seconds – The buzzer emits 3
beeps
4. Open the door completely by means of a memorized transmitter. The buzzer emits a long beep
when the upper limit switch is reached.
5. Put under the door, an object not more than 5cm high. A small piece of wood should be
sufficient.
6. Close the door (in hold-to-run mode) keeping your finger pressed on the transmitter with no
interruption. The door will stop at the obstacle and the control unit will make a long beep.
7. Open the door completely and remove the object.
8. Close the door to verify the correct application of the procedure.
Safety Edge Exclusion in the last 5cm of travel
Please ensure you follow each step before moving onto the next page