Motor limits and set up 

The control panel has to detect the TOP limit before normal operation and each time 

after mains power is turned off and then on again.

It is important to set the motor limits first using either a test lead or the two buttons 

inside the control panel and the limit adjustment screws. 

Using either a test lead or the P1 (down) & P2 (up) hold - to - run buttons inside the control panel:

1.

Run the motor in the down direction until it stops. At this point attach the curtain via the straps 
provided unless already attached.

2.

Fine adjust the bottom limit.

3.

Run the motor up to the top leaving only the bottom piece of the door within the tracks.

4.

Fine adjust top limit.

If the door runs higher than needed reduce the travel via the below steps:

To increase the travel turn the limit screw towards the ‘+’ direction.

To reduce the amount the door travels turn the limit to the ’-’ direction.

Tip:

Right hand motor - RED = Down limit - WHITE = Up limit 

Left hand motor - WHITE = Down limit - RED = Up limit 

P1

P2

To Exit Hold - to - run set up mode press the P1 & P2 buttons 

together for 3 times on the 3

rd

press hold until it beeps and 

both L1 & L2 lights go out. The panel is now in Day to Day 
running mode.

Limit 

Adjuster

Limit 

Adjuster

Arrows 

indicate 

Direction 

of rotation 

for the 

tube motor

Hold - to - run set up mode

If the door is moving in the wrong direction:

a. STOP the manoeuvre

b. Switch off the control unit

c.

Swap BLACK & BROWN motor wires over – terminals 5 & 7

d. Power up the board again – go back to bullet point 1

Please ensure you follow each step before moving onto the next page

Summary of Contents for Simple Panel

Page 1: ...Teleco Simple Panel Set up guide Wired safety edge system...

Page 2: ...own 7 Wiring the motor into the control panel Please ensure you follow each step before moving onto the next page Please ensure when fixing the control panel to the wall you use the template provided...

Page 3: ...Safety Edge Set Up Your spiral cables comes pre wired into the junction box so all you need to do is wire the opposite end into the control panel If correctly wired and no fault exists the green LED l...

Page 4: ...f the door runs higher than needed reduce the travel via the below steps To increase the travel turn the limit screw towards the direction To reduce the amount the door travels turn the limit to the d...

Page 5: ...econds until L1 L2 lights flash rapidly you will hear a long beep 2 Release both buttons then a quick press release P2 then press hold P2 circled at the same time press the top button on your transmit...

Page 6: ...hts flash rapidly you will hear a long beep 2 Press hold the P2 circled button at the same time press the selected button on your transmitter 3 The long beep will change to a rapid beep this means the...

Page 7: ...in the control panel 5 times and hold on the 5th press you will hear rapid beeps from the control panel 3 Keep hold of the P1 button until you hear a long beep this will take approx 10 seconds 4 When...

Page 8: ...door completely by means of a memorized transmitter The buzzer emits a long beep when the upper limit switch is reached 5 Put under the door an object not more than 5cm high A small piece of wood shou...

Page 9: ...position To alter the dip switches this must be done within 30 seconds of powering on the control panel Dip switch positions The dips switches are pre set and should not need to be touched as shown 1...

Page 10: ......

Reviews: