15
The temperature sensor (NTC 10K/3435K) activates whenever there is danger of ice forming.
TEMPERATURE sensor
3.5
ALARM ACTIVATED when
What happens with ALARM ACTIVATED
ALARM NOT ACTIVE when
The measured temperature is below 2 °C .
The control unit tilts the pergola slats to 10% of full opening.
The measured temperature is above 3 °C or
any command is received
TEM
PÉRATURE
t
°
To manage the alarm associated with snow, the temperature (NTC 10K/3435K) and the rain sensors must be combined.
SNOW condition
3.3
SNOW
Factory setting
DEACTIVATED
Warning:
if the temperature probe contact (13-14) is open (not connected) and the alarm is triggered, the control unit tilts the slats of the pergola to
66%
of the
full opening with intermittent movements.
LR flashes
3.4
Activation/deactivation RAIN sensor or SNOW condition (rain+temperature)
ALARM ACTIVATED when
What happens with ALARM ACTIVATED
ALARM NOT ACTIVE when
The measured temperature is below 2 °C and
rain has been detected.
The control unit tilts the slats to
66%
of full opening. The control
unit only executes
hold-to-run commands
.
The measured temperature is above 3 °C or rain is
no longer detected. When the control unit receives a
command for automatic movement by transmitter, it
exits the alarm status.
STOP
(10 s)
continuous
sound
STOP
(10 s)
Sensor deactivation (60 minutes)
Press the “
STOP
” button of a memorized 7/42
or 3-channel transmitter for
10 s.
The buzzer emits
2 beeps
.
Sensor activation
Press the “
STOP
” button of a memorized 7/42
or 3-channel transmitter for
10 s.
The buzzer
emits a continuous sound.
ACTIVE ALARM when
Once ACTIVE ALARM
DEACTIVATED ALARM when
The sensitive surface of the sensor
detects any drops of water.
The control unit moves the louvres to the complete closing and
it
doesn’t execute any command
.
LR
is ON.
The sensor doesn’t detect any drop.
RAIN sensor
3.2
RAIN
LR ON
Factory setting
ACTIVATED