4) Press
the
Fan speed
key repeatedly
until the desired fan speed appears.
5.10 Heating mode
1) Press
the
On/Off
key.
2) Press the
Mode
key
repeatedly until the display
shows the
Heating
symbol
3) Select the desired temperature using
the
Increase temperature
or
Decrease temperature
keys.
4) Press
the
Fan speed
key repeatedly
until the desired fan speed appears.
The heat pump is effective for
outside temperatures down to
-2°C , below this temperature, its
efficiency is considerably
reduced.
If the air conditioner
shuts down when in heating mode the fan
will continue running for several minutes
to disperse the heat accumulated inside
the conditioner itself. The fans then shut
down automatically
A flashing Fan Speed
symbol on the display indicates that no
speed has been chosen.
5.11 Diffuser
Display
The diffuser has a display which also
incorporates the remote control receiver.
When the red light (
Fig. 20 ref. A
) next to the
legend “Power” is on the air conditioner is
powered by the 230 Vac power supply.
When the green light (
Fig. 20 ref. B
) next to
the legend “Run” is on the air conditioner is
working in the conditioning mode; if, instead,
the red light (
Fig. 20 ref. B
) next to the
legend “Run” is on the air conditioner is
working in the heating mode.
The display also shows two numbers (
Fig. 20
ref. C
) that indicate temperature.
While you are selecting the desired
temperature via the remote control the
diffuser display will show the temperature
selected at that moment.
About a minute after the end of selection, and
during the entire time the conditioner is
running, the display indicates the current in-
camper temperature.
5.12 Cleaning the filters
Periodically clean both diffuser filters: wash
with a neutral detergent only and dry them
thoroughly before putting them back in their
seats (fig.
21
).
6
SAFETY REGULATIONS
•
Always use properly earthed power
sockets with differential safety switches.
•
Never use the air conditioner near
flammable liquids.
•
Do not use the air conditioner for
purposes other than those stated by the
manufacturer.