30 and 60 mm. With thicker roofs, a larger conveyor
will be required.
Do not crush the sealing liner
too much: it must not be less than 12 mm thick.
If you crush the liner too much, this will damage
the supporting base of the air conditioner,
compromising the sealing of the joint and
generating loud noise inside the vehicle when
working.
5.4 Installing the diffuser
After anchoring the evaporating unit to the roof of
the vehicle, take both cold air outlet flaps out of the
diffuser
Fig. 16
.
Fit the probe of the thermometer into the rubber tab
on one side of the aluminium conveyor
Fig. 17 Ref.
(2)
. Connect the cable of the control unit
Fig. 17
Ref. (3)
.
Apply the diffuser to the conveyor. Make sure that
the aluminium tunnel is properly placed at the very
centre of the diffuser.
Reunite the two pipe couplings (after wrapping them
in condensate-proofing material) inside the area
covered by the diffuser.