Performance Tests
1–92
TDS 500D, TDS 600B & TDS 700D Performance Verification and Specifications
Table 1–10: Option 3C and 4C Specifications (not available on TDS 794D)
Name
Description
Calibration Range, Reference Receiver
10
m
W per division
20
m
W per division
50
m
W per division
Temperature Range, Warranted Filter
23
_
C,
"
5
_
C
Calibration Range, Controlled
Up to 2X the data rate for all filters except
FC1063 filter
Up to 1.5X the data rate for FC1063 filter
Table 1–11: Available receivers
Option 4C
1
Option 3C
2
OC1
4
OC3
OC12
FC1063
3
FC133
FC266
FC531
FC1063
3
OC3
OC12
TDS 520D
n
n
n
n
TDS 540D
n
n
n
n
n
n
n
n
TDS 580D
n
n
n
n
n
n
n
n
n
n
TDS 724D
n
n
n
n
TDS 754D
n
n
n
n
n
n
n
n
TDS 784D
n
n
n
n
n
n
n
n
n
n
1
Requires Tektronix P6703B, 1300 nm Optical to Electrical Converter.
2
Requires Tektronix P6701B, 850 nm Optical to Electrical Converter.
3
Reference receivers are warranted to 2.0 times the bit rate except for FC1063 which is warranted to 1.5 times the bit rate.
4
OC1 is type tested
Summary of Contents for TDS 500D
Page 4: ......
Page 15: ...Performance Verification Procedures...
Page 16: ......
Page 119: ...Specifications...
Page 120: ......
Page 130: ...Specifications 2 10 TDS 500D TDS 600B TDS 700D Performance Verification and Specifications...
Page 138: ...Nominal Traits 2 18 TDS 500D TDS 600B TDS 700D Performance Verification and Specifications...
Page 153: ......
Page 154: ......