Service Guide
41
Inspecting the power supply fuses
The 115 VAC power supply features a 8 A and a 10 A fuse. The 220 VAC power supply
fuse uses a 4 A and a 5 amp fuse.
1.
Turn off the printer.
2.
Remove the power supply.
3.
Remove the power supply cover to access the fuses.
4.
Visually, and with a VOM, check to determine that the fuse is in working order.
If the fuse is good, but the printer's power supply does not output DC voltages,
proceed to the next topic, “Testing for a shorted motor.”
Safety interlocks
The printer features four safety interlock switches:
■
Front door-opened switch.
■
Right side door-opened switch.
■
Left door-opened switch.
■
Optional Lower Tray Assembly door switch.
When any of the switches are opened, the +24 VDC supply to the motors is shut
down, as well as the high-voltage power supply.
1.
Test the functionality of the interlock using the service tests described in “Phaser
740 service tests” on page 77.
2.
Turn off the printer.
3.
With a VOM, set to measure resistance, test each switch when it is opened and
closed.
4.
Inspect each switch’s wiring harness for pinches, nicks or open connections.
If you find a switch that is defective, replace it.
If the switches work correctly and the DC voltages are correct, then the problem may
be an open or otherwise faulty motor.
Summary of Contents for Phaser 740
Page 6: ......
Page 48: ...36 Phaser 740 and 750 Color Printers ...
Page 102: ...90 Phaser 740 and 750 Color Printers ...
Page 104: ...92 Phaser 740 and 750 Color Printers ...
Page 124: ...112 Phaser 740 and 750 Color Printers ...
Page 129: ...Service Guide 117 Figure 3 Motor and fan FRUs 3102 37 1 10 9 5 8 7 2 6 4 3 ...
Page 131: ...Service Guide 119 Figure 4 Sensor switch and flag FRUs 3102 40 1 7 2 3 4 8 5 6 ...
Page 135: ...Service Guide 123 Figure 6 Imaging and paper feed component FRUs 3102 39 1 2 3 7 9 4 6 8 5 ...