Commands listed in alphabetical order
CH<x>:PROBEFunc:EXTDBatten
This command sets or queries the input-output ratio (expressed in decibel units) of
external attenuation or gain between the signal and the instrument input channels.
The channel is speci
fi
ed by x.
The query form of this command returns the user-speci
fi
ed attenuation in decibels.
Group
Vertical
Syntax
CH<x>:PROBEFunc:EXTDBatten <NR3>
CH<x>:PROBEFunc:EXTDBatten?
Related Commands
Arguments
<NR3>
is the attenuation value, which is speci
fi
ed in the range from -200.00 dB
to 200.00 dB.
Examples
CH3:PROBEFUNC:EXTDBATTEN 2.5
speci
fi
es an external 2.5 dB attenuator
on Channel 3.
CH1:PROBEFUNC:EXTDBATTEN?
might return
:CH1:PROBEFUNC:EXTDBATTEEN 2.5000E+00
, indicating that the attenuation
for Channel 1 is 2.5 dB.
CH<x>:PROBEFunc:EXTUnits
This command sets the unit of measurement for the external attenuator of the
speci
fi
ed channel. The channel is speci
fi
ed by x. The alternate units are used if
they are enabled. Use the
CH<x>:PROBEFunc:EXTUnits:STATE
command to
enable or disable the alternate units.
Group
Vertical
Syntax
CH<x>:PROBEFunc:EXTUnits <QString>
CH<x>:PROBEFunc:EXTUnits?
Related Commands
Arguments
<QString>
indicates the attenuation unit of measurement for the speci
fi
ed
channel.
2-202
MSO54, MSO56, MSO58, MSO58LP Programmer
Summary of Contents for MSO54
Page 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Page 2: ......
Page 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Page 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Page 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Page 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...