
Command Descriptions
Table 2-27: Measuring functions and parameters (cont.)
Measuring functions
Parameters
[VOLTage:]MAXimum
(@1|@2)
[VOLTage:]MINimum
(@1|@2)
[VOLTage:]PTPeak
(@1|@2)
[VOLTage:]RATIO
(@1|@2),(@1|@2)
<(@{1|2|3|4|6})> is the channel to measure on, where:
(@1)
means input A
1
(@2)
means input B
1
(@3)
means input C (RF input option),
(@4)
means input E (Rear panel arming input)
(@6)
means the internal reference
NOTE.
The channel is expression data and it must be in parentheses ( ).
1
These channels are prescaled by 2 when measuring frequency, and prescaled by 1 for all other
functions. An exception is burst frequency measurements, where you can choose between
the two factors. See the
command and the command
FREQuency:BURSt:PREScaler[:STATe]
. There is a tradeoff between the minimum number of
pulses in a burst and the frequency range.
Examples
CONF:ARR:PER (7),5E3,1E6,(@4)
This example sets up the instrument to make seven period measurements. The
expected result is 5 ms, and the required resolution is 1 ms. The EXT ARM
input is the measuring input.
To make the measurements and fetch the seven measurement results:
READ:ARRAY? 7
might return
5.23421E-3,5.12311E-3,5.87526E-3,
5.50345E-3,5.33901E-3,5.25501E-3,5.03571E-3
CONFigure:<MeasuringFunction>
Use the con
fi
gure command instead of the measure query when you want
to change other settings, for instance, the input settings before making the
measurement and fetching the result.
The CONFigure command controls the settings of the Input, Sense and Trigger
subsystems in the instrument in order to make the best possible measurement. It
also switches off any calculations with CALC:STATE OFF.
2-48
FCA3000, FCA3100, MCA3000 Series Programmer Manual
Summary of Contents for FCA3000 Series
Page 2: ......
Page 8: ...Preface iv FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Page 9: ...Getting Started ...
Page 10: ......
Page 14: ...Using the USB Interface 1 4 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Page 15: ...Syntax and Commands ...
Page 16: ......
Page 26: ...Command Syntax 2 10 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Page 135: ...Status and Events ...
Page 136: ......
Page 156: ...Status and Events 3 20 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Page 157: ...Programming Examples ...
Page 158: ......
Page 179: ...Appendices ...
Page 180: ......
Page 181: ...Appendix A Character Set FCA3000 FCA3100 MCA3000 Series Programmer Manual A 1 ...
Page 182: ...Appendix A Character Set A 2 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Page 188: ...Appendix D Reserved Words D 2 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...