HDMI Compliance & Sink Characterization Using DTG5000 Series Data Timing Generator

Application Note

10

www.tektronix.com/signal_sources

10

Test Adapters

The approach using the DTGM32 and the AFG allows

for thorough compliance and pre compliance testing

with a much simpler setup than the AWG method. 

This method was designed for pre/compliance testing

only since the maximum available jitter just meets

specification requirement. If testing is required above

the specification (as in characterization), then the

AWG method would be the recommended solution.

Reliable connections are key to maintaining precision

and signal integrity for all HDMI tests. There are two

types of test adapter sets available. For most of the

Sink tests devices, the plug-type adapters (TPA-P) set

and receptacle-type adapters (TPA-R) set are well 

suited for making the primary connection to the

Device-under-test (DUT). Figure 9 shows a TPA-P

plug-type test adapter.

Figure 9.

TPA-P-TDR (013-A013-50) adapter.

Table 4.

DTG5000 Series files used by TDSHT3 in HDMI compliance tests.

DTG5000 Series Files Used in HDMI Compliance Test by TDSHT3

Test

Pix Clock

861B ID

Filename

Type

Image

Description

Sink 

Minimum 

25.2 MHz

480 p@60 Hz

640x480 p 60 Hz.dtg

8-5

Diff. Sensitivity

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz.dtg

US

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz.dtg

EU

Normal

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz.dtg

US

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz.dtg

Sink 

Intra-Pair Skew

25.2 MHz

480 p@60 Hz

640x480 p 60 Hz IP.dtg

8-6

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz IP.dtg

US

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz IP.dtg

EU

Diff. Timing Offset

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz IP.dtg

US

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz IP.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz IP.dtg

Gray RGB

Sink 

Jitter Tolerance

25.2 MHz

480 p@60 Hz

640x480 p 60 Hz.dtg

8-7

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz.dtg

US

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz.dtg

EU

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz.dtg

US

Normal

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz.dtg

Cable 

Cable Data 

27.027 MHz

480 p@60 Hz

720x480 p 60 Hz CT.dtg

US

5-3

Eye Diagram

27.0 MHz

576 p@50 Hz

720x576 p 50 Hz CT.dtg

EU

74.25 MHz

1080 i@60 Hz

1920x1080 i 60 Hz CT.dtg

US

VH=3.3 V VL=2.9 V

74.25 MHz

720 p@50 Hz

1280x720 p 50 Hz CT.dtg

EU

148.5 MHz

1080 p@60 Hz

1920x1080 p 60 Hz CT.dtg

Most Likely Test Condition

Optional

Only If The Maximum Is 27MHz

27.027 MHz

27.0 MHz

27.027 MHz

27.0 MHz

74.25 MHz

74.25 MHz

148.5 MHz

27.027 MHz

27.0 MHz

74.25 MHz

74.25 MHz

148.5 MHz

27.027 MHz

27.0 MHz

74.25 MHz

74.25 MHz

148.5 MHz

Summary of Contents for DTG5000 Series

Page 1: ...HDMI include LCD displays plasma displays and projection units Thanks to the simplicity of setup and the resulting quality of the presentation consumers are accepting HDMI as a must have item for the...

Page 2: ...bility and accordingly customer satisfaction Today these tests can only be performed at an HDMI Authorized Testing Centers ATC Pre compliance testing during the design and manufacturing stages greatly...

Page 3: ...published HDMI specifications a device manufacturer can pave the way for a new product s acceptance in the marketplace Testing should also ensure that the designs are robust enough to withstand the ha...

Page 4: ...for HDMI Using TDSHT3 HDMI Compliance Test Software available at wwww tektronix com This balance of this technical brief will concentrate on the equipment and procedures for compliance and characteriz...

Page 5: ...ent criteria for D_JITTER and C_JITTER margins The tests need to be performed at all pixel clock rates supported by the device under test Because of the many parameters to be adjusted and the tight ma...

Page 6: ...ements Tolerance Sensitivity Intra Pair Skew Remarks Digital Storage Oscilloscope 16M record length Differential Probes 2 ea TPA R Test Adapter Set 013 A012 50 TPA P Test Adapter Set 013 A013 50 12 SM...

Page 7: ...th its four input channels 4 GHz bandwidth and 20 megasample per second sample rate is a good match for HDMI measurements Data Timing Generator The stimulus source generator that provides the TMDS sig...

Page 8: ...generates the specific jitter modulation waveform and sends it to the AWG710B which in turn acts as the clock source for the jitter tolerance test The jitter is steadily increased by the software unt...

Page 9: ...ired jitter content Figure 7 depicts this scheme The DTGM32 module allows jitter components to be added to its output The jitter amplitude is controlled by the input amplitude of the jitter source in...

Page 10: ...itivity 27 027 MHz 480 p 60 Hz 720x480 p 60 Hz dtg US 27 0 MHz 576 p 50 Hz 720x576 p 50 Hz dtg EU Normal 74 25 MHz 1080 i 60 Hz 1920x1080 i 60 Hz dtg US 74 25 MHz 720 p 50 Hz 1280x720 p 50 Hz dtg EU 1...

Page 11: ...ns Typically there is a region within this opening that must not be violated by any waveform data point To do so would indicate insufficient signal amplitude slow rise or fall times jitter or a combin...

Page 12: ...8 5299 Russia CIS 7 095 775 1064 South Africa 27 11 254 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom Eire 44 0 1344 392400 USA 1 800 4...