IL603 Tek-SELECT

®

II Manual  • Page 9

Figure 8 — SM406 Master to Master

Wiring Diagram

Figure 9 — SM406 Master to Remote

Wiring Diagram

C

X

R E M O T E

I N D O O R

IR141P

C

X

O U T D O O R

R E M O T E

OR610

C

X

R E M O T E

I N D O O R

IR141P

H

C

X

H

C A L L B U T T O N

S F 4 0 0

C

X

R E M O T E

I N D O O R

IR510B

T R A N S F O R M E R

SS106

R E L E A S E

P O 0 0 1

D O O R

P A G I N G H O R N

S B 2 0 5 A

T R A N S F O R M E R

25V AUDIO

D 1

D 2

T 1

T 2

R 2

E 1

E 2

N

P

L

C

M

R 1

D

P O W E R S U P P L Y

PK400

P

1

B

N

A

11

12

2

3

8

7

9

10

5

4

6

R E L A Y

ALL CALL

RY401

D

P

F

N

B

A

4

5

M

1

3

X

2

6

C

R

L

SM406

M A S T E R

C

X

O U T D O O R

R E M O T E

OR642/OR642W

T R A N S F O R M E R

SS106

24 V.A.C.

F O O T S W I T C H

7. If the paging horn is not connected to the all call relay, the 25V audio transformer is not needed.

NOTES:

2. Connect power transformers to 115 V.A.C. in accord with local electrical codes.

4. If a lighted outdoor remote is not used, it is not necessary to use terminals E1 and E2.

6. If the SF400 call button is not used, replace it with an EC105 capacitor in series.

1. Actual terminal locations not shown. See terminal identification diagrams.

5. If the door release is not used, delete connection to terminals D, and D1.

3. For wire size and maximum length, see the installation instructions.

Summary of Contents for Tek-SELECT II SM401

Page 1: ...unication is needed Multicolored signal lights hands free reply privacy and monitoring are all standard features Optional equipment is available to call all stations distribute music and control remot...

Page 2: ...raciesthatmayappearinthis documentation TekTone the TekTone logo Tek Call Tek Care Tek Check In Tek Com Tek Digicare Tek Door Tek Entry III Tek Guard Tek Micro Tek MMARS II Tek NIOS Tek Paging Tek Pho...

Page 3: ...ume Adjustment 3 1 9 Terminal Reference for Master 3 2 0 OPERATING INSTRUCTIONS 2 1 Master Station 5 Call another station 5 Answer a call from a master at a remote 5 Answer a call from a master at a m...

Page 4: ...strike RY400 Remote control relay 3 outputs RY401 All call relay for 12 stations RY402 In use adapter SB205A Paging horn requires EC105 capacitor and transformer SF400 Call button for use with paging...

Page 5: ...cal power Locate the transformer within 50 feet 15 meters of the power supply and at least 3 feet 1 meter from master stations remote stations and intercom wiring Do not locate transformers near any s...

Page 6: ...any part of the system to AC power lines Do not connect transformer to power source until wiring is complete 1 6 Equipment Installation Surface Mounting SM404 SM406 and SM411 Masters 1 Install IH401...

Page 7: ...400 remote control relay is installed Violet F When this line is shorted to the N connection through a dry contact the master switches from listen to talk A selector button must be pushed in for this...

Page 8: ...Page 4 IL603 Tek SELECT II Manual...

Page 9: ...lights Answer a call from a master at a master 1 Calls from masters are not indicated by a light but may be preceded by a short tone signal Master calls are announced by voice 2 To answer a If the PR...

Page 10: ...Page 6 IL603 Tek SELECT II Manual...

Page 11: ...IME DIP SWITCH DETAIL 6 OFF ON 1 3 CONNECTOR 2 5 4 1 2 9 11 7 6 8 O R A N G E BLUE G R E E N B R O W N R E D 3 B L A C K B R O W N W H I T E RED WHITE VIOLET WHITE GREY 10 CONNECTOR 1 D N B A P M L X...

Page 12: ...9 8 11 7 M X 5 6 10 1 3 2 4 MASTER SM411 T1 D2 T2 R2 D1 L N P M E1 E2 R1 D C POWER SUPPLY PK400 F R N C L P D B A X 9 11 7 M 8 5 6 10 1 3 2 4 MASTER SM411 F R N C L P D B A 10 9 11 7 M 8 5 6 X 1 3 2 4...

Page 13: ...6 C R L SM406 MASTER C X OUTDOOR REMOTE OR642 OR642W TRANSFORMER SS106 24 V A C FOOT SWITCH 7 If the paging horn is not connected to the all call relay the 25V audio transformer is not needed NOTES 2...

Page 14: ...EMOTE D2 D1 R2 T2 T1 M L E1 C P D R1 N E2 POWER SUPPLY PK400 A P B C R L N D F K2 3 K6 M X 1 K1 K3 K4 K5 4 6 2 5 MASTER SM406 TRANSFORMER SS106 TRANSFORMER SS106 24 V A C X3 K2 K3 K1 S3 S2 X2 X1 ADAPT...

Page 15: ...ease is not used delete connections to terminals D and D1 5 RY402 should always have a direct connection to the PK400 s N terminal 2 Connect power transformers to 115 V A C in accord with local electr...

Page 16: ......

Reviews: