System Operating Instructions
IL380 Tek-CARE
®
NC150 & NC200 Manual • 5
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.
IR150B Staff Stations
Refer to
Figure 2
for locations, names and functions of controls and indicators.
Call the NC150N or NC200N Master Station: Press the
call
button. The call-placed lamp
will illuminate to indicate call placement. When the call is answered, the call-placed
lamp will go off and the
in
use
LED will illuminate to indicate a communication path
has been established to the master station. Speak in a normal voice.
Cancel a Call: Press the
reset
button.
call
placed
lamp will go off.
Improper Operation: Contact qualified service personnel if the station does not op-
erate as described. There are no user serviceable parts on the IR150B Staff Station.
IR151B, IR152B Patient Stations
Refer to
Figure 2
for locations, names and functions of controls and indicators.
Call a Nurse: Press the
call
button located on the end of the call cord. The
call
placed
lamp will illuminate to indicate call placement. When the nurse answers, the
call
placed
lamp will go off and the
in
use
LED will illuminate to indicate that a com-
munication path has been established with master station. When the nurse speaks,
reply in a normal voice.
NOTE: If the call cord is pulled from its receptacle, a
call will be placed automatically and cannot be canceled until the call cord is
replaced in the receptacle.
Cancel a Call: Press the
reset
button. The
call
placed
lamp will go off.
Improper Operation: If the patient station does not operate as described, contact
qualified service personnel. There are no user serviceable parts on the IR151B,
IR152B Patient Stations other than call cords.
IR155B Patient Stations
Refer to
Figure 2
for locations, names and functions of controls and indicators.
Call A Nurse: Pull the cord. The
call
placed
lamp will illuminate to indicate call place-
ment. When the nurse answers, the
call
placed
lamp will go off and the
in
use
LED
will illuminate to indicate that a communication path has been established with the
master station. When the nurse speaks, reply in a normal voice.
Cancel a Call: Call must be canceled at the point of origin. Push the
reset
switch to the
left. The
call
placed
lamp will go off.
Improper Operation: If the station does not operate as described, contact qualified
service personnel. There are no user serviceable parts on the IR155B Patient Station.
SF155B Emergency and SF156B Code Stations
Refer to
Figure 2
for locations, names and functions of controls and indicators.
Call a Nurse: Pull the call cord, or slide the call/cancel switch down. The
call
placed
lamp will flash. Wait for the nurse.
Cancel a Call: Push the call/cancel switch up. The
call
placed
lamp will go off.
Improper Operation: If the call station does not operate as described, contact qualified
service personnel. There are no user serviceable parts on the SF155B Emergency
Call and SF156B Code Call Stations.
System Operating Instructions