background image

Kona Enterprise Gateway 

T0007323_UG 

Version 1.3 

TEKTELIC Communications Inc. 

Confidential 

Page 11 of 15 

2.4

 

Required Equipment for Installation 

The following tools are required to install the Kona Enterprise Gateway module: 

1.

 

A 6 point metric socket set and torque wrench drive. 

2.

 

Anti-oxidant compound (NO-OX-ID, Penetrox, Noalox, Ox-Gard or equivalent). 

3.

 

A small wire brush. 

4.

 

A clean cloth. 

5.

 

Weatherproofing tape kit for the RF connector (Scotch Wireless Weatherproofing Kit, WK-
101 recommended). 

6.

 

Supplied pole mounting accessories (shown in Figure 6) for pole mounting or appropriate 
screws  or  bolts  (four  sized  M6)  with  any  required  anchors  according  to  the  wall 
construction for wall mounting. 

 

2.5

 

Kona Enterprise Gateway Mounting 

Kona Enterprise Gateway PoE 

must

 be mounted to a vertical pole or wall using the supplied 

mounting hardware which attaches to the back of the module as illustrated in 5. The vertical 
orientation is required for the GPS to function properly. 

 

Summary of Contents for KONA ENTERPRISE T0007242

Page 1: ...disclosure to all third parties 2020 TEKTELIC Communications Inc all rights reserved All products names and services are trademarks and registered trademarks of their respective companies TEKTELIC Communications Inc 7657 10th Street NE Calgary AB Canada T2E 8X2 Phone 403 338 6900 KONA ENTERPRISE GATEWAY USER GUIDE Document Type User Guide Document Number T0007323_UG Document Issue 1 3 Document Sta...

Page 2: ...ment Revision Revision Issue Date Status Editor Comments 0 1 Nov 19 2020 Draft H Agus First release 1 0 March 23 2021 Draft Chathula Adikary 2nd Revision 1 1 April 14 2021 Draft H Agus 3rd Revision 1 2 April 19 2021 Draft SM Updated power specification 1 3 May 20 2021 Released ZH Updated T Codes Order Codes ...

Page 3: ...ription 5 1 1 Overview 5 1 2 Physical Interfaces 7 1 3 Specifications 8 2 Installation 9 2 1 Overview 9 2 2 Unpacking and Inspection 10 2 3 Dual SIM Slot Operation 10 2 4 Required Equipment for Installation 11 2 5 Kona Enterprise Gateway Mounting 11 2 6 Ground Cable Installation 13 2 7 RF Cable Installation 14 2 8 Copper Ethernet Cable Installation 15 ...

Page 4: ..._UG Version 1 3 TEKTELIC Communications Inc Confidential Page 4 of 15 List of Tables Table 1 Kona Enterprise Gateway Models 5 Table 2 Kona Enterprise Gateway Interface Connector Types 7 Table 3 Kona Enterprise Gateway Specifications 8 ...

Page 5: ...lk connector The Kona Enterprise Gateway is powered through Power Over Ethernet PoE 802 3af Table 1 presents the currently available Kona Enterprise Gateway models Table 1 Kona Enterprise Gateway Models Model Order Code 3G 4G modem Region Frequency Band T0007242 MOEN1LUS915 Yes North America 915 T0007422 MOEN1NUS915 No North America 915 T0007358 MOEN1LEU868 Yes Europe 863 870 T0007358 MOEN1LIN868 ...

Page 6: ...o Taiwan 922 928 T0007435 MOEN1LTW923 Yes Taiwan 922 928 T0007422 MOEN1NAU915 No Australia 915 928 T0007435 MOEN1LAU915 Yes Australia 915 928 Figure 2 illustrates the Kona Enterprise Gateway external form factor All models share the same mechanical form factor Figure 1 Kona Enterprise Gateway Figure 2 Kona Enterprise Gateway ...

Page 7: ...ise Gateway Interface Connector Types Interface Connector Type Mating Connector LoRa Antenna N Type female Industry standard N Type male Cellular Antenna N Type female Industry standard N Type male Copper Ethernet RJ45 Modular Jack RJ45 modular plug followed by CAT 5e cable Earth Ground Compression lug Industry standard single hole lug M4 8 Protective Earth Ground Optional LTE Antenna connection E...

Page 8: ...0 C to 60 C Relative Humidity 10 to 100 Condensing Operating Altitude 60 m to 4 000 m 197 ft to 13 123 ft Power Input IEEE 802 3af Mode A or Mode B or 4 pair Mode 48 VDC nominal 37 to 57 VDC operating range 0 3 A maximum Ingress Protection IP 67 Regulatory Compliance Safety UL CSA EN IEC 62368 1 Radiated Immunity EN 61000 4 3 ESD Immunity EN 61000 4 2 EFT Immunity EN 61000 4 4 Conducted Immunity E...

Page 9: ... port The primary lightning protectors have the ability to bridge the interface to chassis during over voltages Ensure that the Protective Earth Ground connection is always in place An external inline surge protector must be applied to the External Cellular antenna port when used Ensure that the Kona Enterprise Gateway is secured to eliminate any physical hazard to people or property The Gateway m...

Page 10: ...eturned for repair or re configuration 2 3 Dual SIM Slot Operation The Kona Enterprise Gateway is equipped with a dual SIM slot which can be configured to the user s liking The primary and secondary slots can be configured in the software configuration Prior to inserting or replacing SIM please ensure that the unit is turned off If 2 SIM cars are used and the primary SIM fails or is missing the fa...

Page 11: ...loth 5 Weatherproofing tape kit for the RF connector Scotch Wireless Weatherproofing Kit WK 101 recommended 6 Supplied pole mounting accessories shown in Figure 6 for pole mounting or appropriate screws or bolts four sized M6 with any required anchors according to the wall construction for wall mounting 2 5 Kona Enterprise Gateway Mounting Kona Enterprise Gateway PoE must be mounted to a vertical ...

Page 12: ...5 Kona Enterprise Gateway Wall Mounting Screw Locations When mounted the Gateway module must be oriented with the connector bulkhead pointed down towards earth as shown in Figure 6 Figure 6 Kona Enterprise Gateway Module Wall Mounting Orientation Figure 7 Kona Enterprise Gateway Module Pole Mounting Accessories ...

Page 13: ...imum OD to the ground termination point illustrated in Figure 9 The recommended ground cable gauge is 10 AWG The Kona Enterprise Gateway grounding system shall follow local and national electrical codes The Protective Earth Ground conductor terminated at the hole lug point is mandatory and must be the first connection made to the Kona Enterprise Gateway during installation Proper routing and termi...

Page 14: ...ion Point 2 7 RF Cable Installation The Kona Enterprise Gateway installation allows connection to an external LoRa RF antenna and an external Cellular RF antenna The RF cables attach to an N Type connector located on the bulkhead of the Gateway Torque the cable RF connector to 0 79 to 1 13 Nm 7 to 10 in lbs The N Type connector interface to a cable is not water proof and must be taped TEKTELIC rec...

Page 15: ... be used for backhaul or commissioning and maintenance As shown in Figure 10 pass the Ethernet cable through the cable gland supplied with the module Plug the cable into the modular jack on the module then tighten the cable gland to the module with torque 6Nm The Ethernet cable must have minimum 24 AWG conductors and shall be rated according to local and national electrical codes Figure 10 Kona En...

Reviews: