Precautions

 

 

•  Read User Manual before using this system for the first time.
•  Keep this manual available whenever you use your system.
•  The system is intended for personal use on healthy adult muscle only. 
•  The safety of using the system during pregnancy or birth has not been established.
•  The effectiveness of the system depends greatly on a person’s individual physical 
  condition. It may not always be effective for every user.
•  The safety of neuromuscular stimulation during pregnancy has not been established.
•  Use caution when/if:
  - User has skin areas that lack normal sensation.
  - Following surgical procedures if muscle contractions might impede healing process.
  - Over a menstruating or pregnant uterus.
  - There is a tendency to hemorrhage following acute trauma or fracture.
•  Place electrodes in accordance with illustrations in the Quick Start Guide.
•  This unit should not be used while driving, operating machinery or during any activity  
  in which involuntary muscle contractions may place the user at undue risk of injury.
•  Some users may experience skin irritation or hypersensitivity due to the electrical  
  stimulation or the conductive medium.
•  Keep the stimulator out of the reach of children.
•  Application of moderate heat (thermal wrap) to muscles as well as moistening skin  
  prior to treatment improves treatment efficacy; use of cold packs on treated muscles  
  after treatment is likewise recommended.
•  This unit should only be used with the leads, electrodes and accessories provided by  
  the manufacturer.
•  The device is not intended for medical use, for the treatment of any medical condition  
  or for any permanent physical changes. 
•  Contact TekSmart Fitness if your unit is not working correctly. Do not use in the  
 meantime. 
•  An effective session should not cause discomfort.
•  For first time users, muscle stimulation can be an unusual sensation. We recommend  
  that you begin in a seated position with low stimulation intensity settings to 
  familiarize yourself with the sensation before progressing to higher intensity settings. 
•  The leads and pads must not be connected to other objects.
•  Do not over exert yourself while using muscle stimulation. Any workout should be at a  
  comfortable level for you. 
•  Do not place pads over jewelry or body piercings.
•  Start all sessions in a sitting position 
 

Summary of Contents for Contour

Page 1: ......

Page 2: ...Turning OFF the Device 8 Selecting the Program 9 Selecting the Exercise Intensity Level 9 SPECIAL FEATURES 10 CARE AND MAINTENANCE 11 TROUBLESHOOTING 13 WL 2413B STIMULATOR TECHNICAL SPECIFICATIONS 13 Warranty 14 Please read this Use and Care Manual carefully before you start using your TekSmart EMS Device Careful reading of the contraindications warnings precautions adverse reactions caution with...

Page 3: ...s has not been established You suffer from cancer The effects of electronic stimulation on cancerous tissue are unknown You are under medical supervision for cognitive dysfunction as you may not be able to comply with safety instructions The unit is in close proximity to shortwave or microwave diathermy equipment or you are connected to high frequency surgical equipment because of risk of device i...

Page 4: ...Do not use this system while sleeping Do not use if you feel numbness Do not use this system in or close to water Do not use the pads over or close to cancerous lesions Do not use the device in the following circumstances when there is a tendency to bleed internally following an injury of fracture following recent surgical procedures when stimulation may disrupt the healing process over areas of s...

Page 5: ...rience skin irritation or hypersensitivity due to the electrical stimulation or the conductive medium Keep the stimulator out of the reach of children Application of moderate heat thermal wrap to muscles as well as moistening skin prior to treatment improves treatment efficacy use of cold packs on treated muscles after treatment is likewise recommended This unit should only be used with the leads ...

Page 6: ...red as skin irritation and it will normally disappear within 30 minutes after the electrodes are removed If the redness does not disappear after 30 minutes from the removal of electrodes do not use the stimulator again until after the excessive redness has disappeared Turn off the stimulator if the stimulation feels unpleasant or does not provide pain relief Keep your system out of the reach of ch...

Page 7: ... your eyes and to your head and face You should stop using the device and should consult with your physician if you experience adverse reactions from the device Conditions that may affect your TekSmart EMS System Since the stimulator is a battery operated electronic system its output performance and safety may be affected greatly in extreme humidity Therefore it is very important to keep the stimu...

Page 8: ... 7 Time remaining 8 CH1 intensity level 9 CH2 intensity level 10 Lock status indicator 11 Battery status indicator 12 Pause indicator 13 Battery compartment 14 Battery cover 88 88 88 Pi8 PAUSE CH1 CH2 MIN MODE CH1 CH2 ON OFF 3 AAA Batteries EMS Device Lead Wires 4 Silicone Electrodes 3 4 oz Tube Conductive Gel Conductive Gel 3 4 oz The Curvassure Butt Toning Shorts ...

Page 9: ...electrode under the pocket lip 3 Insert pin end of the four lead wires through the eyelet hole on the outside of the shorts This can be done on the left side or right side depending on which pocket you prefer to put the device in during your session 4 Slide one Blue tip wire over and out of the upper right eyelet hole Slide the other Blue tip wire down and out of the lower right eyelet hole Slide ...

Page 10: ... In an emergency you may also pull the connector wire s from the device Note To prevent unpleasant electric shocks never remove the device while it is still turned on Selecting the Program The Device offers three different preset training programs The programs differ with respect to varying pulse widths frequencies and ON OFF time 1 Press the MODE button The P will be flashing Press ON or OFF repe...

Page 11: ...intensity level will reset to 0 each time the device turns off including after training sessions or changing the Program during training session Your Contraction Intensity Level For those not familiar with the sensation of ems it can be a little strange As you increase the intensity you will initially feel a tingle in the area under the pads Gradually increase the intensity until you feel your mus...

Page 12: ...ill flash on the display Press MODE again PAUSE will disappear on the display and session will continue The intensity level will stay at your current setting and time will continue to count down Automatic Shut off The device automatically turns off when no button is pressed for 60 seconds The device automatically turns off when the time for your exercise session has elapsed Intensity Level Reset F...

Page 13: ...ect the cables from the stimulator when not in use Do not pull on the cables but rather on the plugs attached to the ends of the cables Store the stimulator with the cables in a clean dry place Electrodes The electrode pads are conductive silicone pad reusable for single person use Take off from the garment after each use wipe off and dry the electrodes with a soft cloth dampened with soap and wat...

Page 14: ...gnetic immunity The device is intended for use in the electromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood con crete or ...

Page 15: ...customer service 13 WL 2413B STIMULATOR TECHNICAL SPECIFICATIONS Channel Dual isolated between channels Pulse amplitude Adjustable 0 80mA peak into 500Ω load each channel Pulse Rate As pre programming operation mode Pulse Width As pre programming operation mode Software ramp up feature Pulse width ramp up when change mode Timer 30 minutes LCD Show modes pulse rate pulse width timer CH1 CH2 intensi...

Page 16: ... to be free from defects in workmanship and materials at the time of delivery The system accessories short and conductive gel for reasons of hygiene they can neither be taken back nor exchanged once used The distributor reserves the right to replace or repair the unit at their discretion HOW TO GET HELP To get assistance or answers to your questions please contact TekSmart Fitness LLC Visit our we...

Reviews: