8. Operation
1. Power Connection to the PSU (sold separately)
One RTI NEO ONE PSU is needed for up to six RTI NEO ONE devices. Make sure that the PSU is
provided with the correct voltage. Wrong voltage could lead to irreparable damages. Please
find the correct voltage data in the synoptical table at the end of this manual. It must be en-
sured that the devices are not directed to people or flammable objects during installation.
Connect a power cable to ‚Power IN‘ at the RTI NEO ONE device and then either to the
left or to the right ‚Power through‘ at the PSU. After that connect the powerCON TRUE1
power cable to ‚Mains IN‘ at the PSU and then to the mains.
A second RTI NEO ONE can either be connected to the other side of the PSU or to ‚Power
through‘ of the first device as illustrated in the connection example above. Each side of the
PSU can power up a maximum of three RTI NEO ONE show laser lights.
2. DMX
The device can be controlled via DMX. One RTI NEO ONE PSU ist needed for up to six
RTI NEO ONE devices (a maximum of three devices on each side). There are two
‚DMX IN‘ interfaces at the rear side of the PSU. One for DMX controllers with 5 pins
and one for DMX controllers with 3 pins. Only use one controller at the same time.
On the rear side of the NEO ONE there are a ‚DMX IN‘ (DMX input) and a ‚DMX OUT‘ (DMX
through) interface.
First connect ‚DMX IN‘ of the NEO ONE PSU via a DMX cable to a DMX controller. Then con-
nect ‚DMX IN‘ of the NEO ONE with a data cable to a ‚Data Cable OUT‘ of the NEO ONE PSU.
‚DMX through‘ at the PSU is intended to Daisy Chain the control signal with a DMX cable
to the ‚DMX IN‘ interface of a further DMX device. ‚DMX OUT‘ at the NEO ONE is intended
to Daisy Chain the control signal with another data cable to the ‚DMX IN‘ of a further NEO
ONE device.
The RTI NEO ONE uses 13 channels as shown here:
Channel
Value
Effect
Comment
1 Red
0 - 255
Red: 0 - 100%
2 Green
0 - 255
Green: 0 - 100%
3 Blue
0 - 255
Blue: 0 - 100 %
4 Pan Coarse
0 - 255
Pan MSB
5 Pan Fine
0 - 255
Pan LSB
6 Tilt Coarse
0 - 255
Tilt MSB
7 Tilt Fine
0 - 255
Tilt LSB
8 Off / Dot / Gobo 0
Blackout
Safety channel
1 - 10
Dot
11 - 20
Rectangle
21 - 30
Triangle
31 - 40
Line horizontal
41 - 50
Line vertical
Manual: RTI NEO ONE
page 10 / 48
51 - 60
2 dots horizontal
61 - 70
2 dots vertical
71 - 80
3 dots horizontal
81 - 90
3 dots vertical
91 - 100
Circle
101 - 110
4 quarter circle
111 - 120
Test picture
241 - 255
Blackout
9 Zoom
0 - 255
Gobo size
active, if value
of channel 8
between 11
and 110
10 Strobe
0
Strobe off
Strobe effect
1 - 127
Strobe speed
2Hz - 12Hz
128 - 255
Grow effect
256 points - 0
points
11 Rotation
pattern Coarse
0 - 255
Rotation MSB
12 Rotation
pattern Fine
0 - 255
Rotation LSB
13 Grating
Selection
0
No grating
If available
1 - 127
Grating 1
128 - 255
Grating 2
3. Interlock (RJ45)
There is an ‚Interlock IN‘ interface on the rear side of the PSU. The Interlock signal is forwar-
ded to the RTI NEO ONE via a data cable (just like the DMX signal).
An interlock connector is provided with the PSU for testing purposes. Use an E-Stop for
your laser shows. If an Interlock / E-Stop is plugged in the PSU, the laser output of the con-
nected RTI NEO ONE devices gets enabled (if key switch is in ‚ON‘ position).
4. Key Switch
There is a key switch on the rear side of the PSU. Please insert the key into the key switch
and turn it to ‚Laser ON‘ position to enable laser output of all connected NEO ONE devices.
Turn the key to ‚Laser OFF‘ to switch off the devices. Please remove the key to avoid unau-
thorized access.
5. Display
It is possible to adjust settings directly at the device by means of the integrated display and
the data entry wheel below it: