| RENT: OPALED |
| OPALED |
via GIUSEPPE DI VITTORIO 9
20037 PADERNO DUGNANO (MI) ITALY
CONTACT US: (+39) 0291082905 - WWW.TEKSET.IT
via NAZARIO SAURO 13/A
20037 PADERNO DUGNANO (MI) ITALY
CONTACT US: (+39) 0291082905 - WWW.TEKSETRENTAL.IT
TekSet
Rental S.r.l.
RGB DMX POWER SUPPLY 2G
rev: 04
17
www.mbnled.com
Lower right display:
Various icons
DMX
– DMX signal present at the input
MST
– Device is in master mode and sends a DMX signal
IR
– IR module is activated
IR displayed inverted
– an IR signal is received from the remote control
MAIN MODE
Setup
– Access to the setup menu items
DMX Address
(1-510)
Manual
– Desired colour can be adjusted manually with the buttons
Single
– Standalone programs can be selected
Master Mode
– Standalone programs can be selected and the DMX signal is sent to
additional devices for sonchronization.
Select main mode:
With the UP-DOWN buttons the main mode is selected. On the right side a little
menu with the main menu items is displayed. By pressing the UP-DOWN buttons you
can select the menu items. When the item is highlighted, the function can be
activated by pressing the ENTER button. When you press the ESC button or if no
button is pressed for 10 seconds, the device will revert to the perviously selected
main mode.
RGB DMX POWER SUPPLY 2G
rev: 04
18
www.mbnled.com
MAIN MODE – DMX ADDRESS
The three large numbers indicate the DMX address.
As long as the digits are flashing, no DMX signal is received. When the display stops
flashing, a DMX signal is present.
DMX address setting:
Press the ENTER button.
With the UP-DOWN buttons you can now select the address from 1-510. By pressing
the ENTER button once more, the slave addresses of the slave devices can be
selected faster and easier. The difference between slave device and DMX address
is, that when configuring the slave devices the DMX address is always changed in
steps of 3. This is a simplification when you have to configure many devices (e.g. in
master-slave mode). One master can control up to 19 slave devices.
Press the ENTER button to save the changes. You can leave this mode at any time
without saving changes by pressing ESC button.
MAIN MODE – MANUAL
Here the current intensity values of the channes (RGB) are displayed. The numbers
indicate the intensities from 0 to 100% and the DMX value from 0-255.
Press the ENTER button and channel red, green or blue starts flashing. Now you can
adjust the value with the UP-DOWN buttons. By pressing the ENTER button again
you can select the next channel. After the last channel all channels are flashing. Here
you can change the values of all three channels together.
If DMX prority is activated (see: SETUP MENU – DMX PRIORITY) these manually
entered values are overwritten by the DMX values.
You can leave this mode at any time without saving changes by pressing the ESC
button.