6.4
Isolation & Protection
All inputs and outputs feature 2.5kV isolation from each other. In addition, the logic
level outputs (
P2
and
P3
) are each protected against damage from transverse voltage
events via a three-stage network of varistor, auto-resetting fuse, and transient
suppressor diode.
Fuse and varistor protection is
removed
when the switching MOSFET factory
option is fitted. The user
must
provide an external power supply and suitable
fusing to use the MOSFET output option. (See 7.1 TCG 01 High Voltage Output
Option on page 15 for further information on the MOSFET Output option)
Varistor protection and current limiting (nominally 5mA) are employed for protection on
the general-purpose input.
F
Figure 8 – TCG 01 Isolation Zones
Transformer isolation via DC-DC converter is used for the main power supply and for
power to each of the logic output-drive circuits. The serial communications interface is
also separately powered via isolating DC-DC converter. High-speed, fixed delay opto-
isolators are used in each of the time-sensitive signalling paths. The isolation does not
degrade the time accuracy of the output signals, as the fixed delays of the isolating
components (together with the delay associated with the antenna lead-in) are all
internally compensated.