PROGRAMMABLE THERMOSTAT 512 

Two Stage Heat / Heat-Cool

Literature

D 512, U 512

Control

Microprocessor PI control; 

This is not a safety (limit) control

.

Packaged weight

0.46 lb. (210 g), Enclosure J, white PVC plastic 

Dimensions

2-7/8” H x 2-7/8” W x 13/16” D (73 x 73 x 21 mm)

Approvals

CSA C US, CSA 22.2 N

24 and UL 873, meets class B: ICES & FCC Part 15.

Ambient conditions

Indoor use only, 32 to 122°F (0 to 50°C), < 90% RH non-condensing.

Power Supply

24 V (ac) ±10%, 60 Hz, 3 VA

Relay

24 V (ac) 2 A, Latching

Sensors

NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892

Included

None

Optional

tekmar type #: 070, 071, 072, 073, 076, 077, 078, 079.

Limited Warranty 

The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of 

any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of 
such Product sale and acknowledges that it has read and understands same.

The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-
through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited 
Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product 
is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-
through warranty period is for a period of twenty-four (24) months from the production date if the Product is 
not installed during that period, or twelve (12) months from the documented date of installation if installed 
within twenty-four (24) months from the production date.

The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts 
and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to 
the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the 
original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from 
tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product 
liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, sec-
ondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship 
or materials, including any liability for fundamental breach of contract.

The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the war-
ranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defec-
tive Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to 
Purchaser’s agreement and warranty with its customers.

Any representations or warranties about the Products made by Purchaser to its customers which are different from 
or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall 
indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or 
nature which arise out of or are related to any such representations or warranties by Purchaser to its customers.

The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by 
persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, 
alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Prod-
uct was not installed in compliance with tekmar’s instructions and / or the local codes and ordinances; or if due to 
defective installation of the Product; or if the Product was not used in compliance with tekmar’s instructions.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING 
LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIP-
TION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND 
ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY 
LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIM-
ITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION 
DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW. 

Product Warranty Return Procedure

 All Products that are believed to have defects in workmanship or materi-

als must be returned, together with a written description of the defect, to the tekmar Representative assigned to 
the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar 
Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, 
regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact 
information regarding the appropriate Representative.

Limited Warranty and Product Return Procedure

Technical Data

Summary of Contents for D 512

Page 1: ...on pg 1 Display Symbols pg 2 General pg 2 3 Sequence of Operation pg 4 6 Type 512 Two Stage Heating pg 4 Type 512 Heat Cool pg 5 6 Menus pg 6 10 View Menu pg 6 Adjust Menu pg 7 10 Error Messages pg 11...

Page 2: ...ing relay s the thermostat ensures that the relay s remains on or off for a minimum amount of time In order to prevent short cycling of the Cool relay the minimum cooling on time and minimum cooling o...

Page 3: ...eat relay and allows the thermostat to operate the slab between the slab minimum and slab maximum settings If more than one slab sensor is used the slab temperatures are averaged by the thermostat Rem...

Page 4: ...ted to satisfy the requirements of the air sensor Slab Sensor Only Operation When operating with only a slab sensor the on times for the Heat 1 and Heat 2 relays are calculated to satisfy the requirem...

Page 5: ...s requirements In this situation heating and cooling can happen at the same time to prevent the space from overheating This is most likely to occur when the slab is operating at the slab minimum tempe...

Page 6: ...cooling setpoint When operating in the Cool mode there is no interlock between the heating and cooling temperature View Menu 1 of 1 ROOM TARGET The current desired air temperature for the space This...

Page 7: ...an active slab sensor OFF 34 to 122 F OFF 1 0 to 50 0 C ROOM HEAT WAKE Desired temperature for heating during Wake Must have an active air sensor and be set to either Heat or Auto 35 to 100 F 1 5 to...

Page 8: ...o 35 to 100 F 1 5 to 38 0 C ROOM COOL Sleep Desired temperature for cooling during Sleep Must have an active air sensor and be set to either Cool or Auto 35 to 100 F 1 5 to 38 0 C SLAB MINIMUM Wake Mi...

Page 9: ...built in sensor is functional or not This item is only available in the Installer access level OFF ON HEATING CYCLE Determines the number of cycles per hour for the heating equipment This item is onl...

Page 10: ...y available in the Installer access level 0 30 to 10 00 min Adjust Menu 4 of 4 EARLY START Selects whether or not the Early Start feature is active This item is only available in the Installer access...

Page 11: ...ernal sensor and use an auxiliary sensor set to INDR or replace the thermostat After the fault is corrected press any button to clear the error message SENSOR 1 SHORT The auxiliary sensor connected to...

Page 12: ...floor Do not mount the thermostat in a location that may be affected by localized heat sources or cold drafts It may be necessary to install a draft barrier behind the thermostat to prevent air from...

Page 13: ...age or high current device Heat 2 Cool The Heat 2 Cool terminals 8 and 9 are an isolated output There is no power available on these terminals from the thermostat This circuit can operate a low curren...

Page 14: ...User 2 Stage Heat Cool Made in Canada Meets Class B Canadian ICES FCC Part 15 Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2 A Class 2 938 02 512 Switch Settings Installer User 2 Stage Heat Cool Made in Ca...

Page 15: ...ne Pump 24 V ac Class 2 Transformer Made in Canada Meets Class B Canadian ICES FCC Part 15 Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2 A Class 2 938 02 512 Switch Settings Installer User 2 Stage Heat Coo...

Page 16: ...FCC Part 15 T T 1 2 L N M Stage 2 Zone Valve 24 V ac Class 2 Transformer Stage 1 Zone Pump Typical Powered Relay Two Stage with Zone Pump and Zone Valve Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2 A Cla...

Page 17: ...Part 15 2 1 8 7 3 4 5 6 2 1 8 7 3 4 5 6 Stage 2 Zone Pump Stage 1 Zone Pump 24 V ac Class 2 Transformer Unpowered Relay Unpowered Relay Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2 A Class 2 938 02 512 S...

Page 18: ...2009 D512 09 09 18 of 20 Notes...

Page 19: ...19 of 20 2009 D512 09 09 Notes...

Page 20: ...g from ownership or use of the product or from defects in workmanship or materials including any liability for fundamental breach of contract The pass through Limited Warranty applies only to those de...

Reviews: