TEKHMANN TWI-200 B Instruction Manual Download Page 20

20 

1.

Positive socket (+) for connecting cable with electrode holder.

2.

Negative socket for (-) for connecting cable with functional terminal.

3. Potentiometer with a scale. Allows adjusting welding current.
4. Thermostatic indicator. Indicator is off when the machine operates normally. Lit indicator means that
temperature inside the machine is exceeded and the thermic protection has been activated. The 
machine is on but not powered until normal temperature is reached. After cooling the machine will start 
automatically. 
5. Power indicator (green color). 

Machine don’t have Power switch. Smart to contact arc ignition. In

boost condition green light flash. 
6. QC indicator (red color). Include 3 conditions: Over current protection, IGBT protection, Low voltage
protection. 

Technical specifications 

Model 

TWI-200 B 

Rated power 

5.8 

кW 

Rated voltage 

160…250 V 

Rated frequency 

50 (60) Hz 

Current control range 

20-

200 А 

Performance index 

85% 

Operating cycle* 

65% 

Power rate (cos 

ϕ

0.9 

Electrodes 

1.6 - 4.0 mm 

Net weight/Gross weight 

2.9 kg / 3.5 kg 

*Operating cycle: shows the period, within which the machine can generate corresponding current. It is
expressed in %, based on 10 minutes per cycle e.g.: 65% = 6 minutes and 30 seconds of operation, 3 
minutes and 30 seconds of waiting). 

Installation place 

Install the machine in such a way so that ventilation openings are not obstructed (forced circulation). 
Do not allow aggressive steam, dust, humidity etc., inside the machine. 

Connecting the machine to the supply line 

Install the plug which meets standards on the    feeding cable. The plug must be equipped with ground 
tip, which must be connected with yellow-green cable. Prepare the receptacle which meets standards. 
The receptacle must be equipped with a fuse or an automatic circuit breaker. From table 1 determine 
recommended nominal of the fuse at maximum rated consumed current and rated line voltage. 

Table 1 

Before connecting ensure that voltage, indicated on the machine nameplate, complies with the voltage 
and frequency of the mains. 

Fuse nominal, A 

Welding current, A 

Receptacle 

capacity, A 

Cable section, mm 

16 

140 

16 

10 

16 

160 

25 

10-16 

25 

180 

36 

16 

25 

200 

36 

16-20 

25 

250 

36 

20-25 

36 

300 

36 

25 

Summary of Contents for TWI-200 B

Page 1: ...TWI 200 B TWI 200 B Inverter welding machine TWI 200 B UA ENG RU...

Page 2: ...2 CONTENTS 1 3 2 Instruction manual English 18 3 24...

Page 3: ...3 TWI 200 B 11 1 TWI 200 B 220 2 2 2 1 2 1 1 2 1 2 2 1 3...

Page 4: ...4 2 1 4 2 1 5 2 1 6 2 1 7 2 1 8 2 1 9 2 1 10 2 1 11 2 1 12 2 1 13 2 1 14 2 1 15 2 1 16 2 1 17 2 1 18 2 1 19 2 1 20 2 1 21 2 1 22 2 1 23 TEKHMANN 2 1 24 TEKHMANN 2 2...

Page 5: ...5 2 2 1 10 2 2 2 5 40 2 3 3 1 3 1 1 TWI 200 B 220 3 1 2 5 40 80 3 1 3 I 160 250 50 60...

Page 6: ...6 3 1 4 3 2 TWI 200 B 1 1 5800 160 250 50 60 20 200 10 65 20 8 25 6 60 VRD 24 5 85 cos 0 9 1 6 4 0 IP21S F 2 9 3 5 3 10 65 6 30 3 30 VRD 24 5 3 3 TWI 200 B 1 1...

Page 7: ...7 1 2 3 4 5 6 3 4 3 4 1 IGBT 50 30 3 4 2 Hot start Arc force Anti stick 3 4 3 5 3 4 4 4 3 4 5 QC IGBT 3 4 6 3 3 4 7 4...

Page 8: ...8 2 4 1 2 4 2 4 3 2 2 2 16 140 16 10 16 160 25 10 16 25 180 36 16...

Page 9: ...9 25 200 36 16 20 25 250 36 20 25 36 300 36 25 4 4 1 1 2 1 5 4 5 3 6 2 5 5 1...

Page 10: ...10 3 1 6 30 55 50 75 20 45 2 40 70 60 100 30 60 2 5 50 100 70 120 40 80 3 2 80 140 110 160 70 130 4 120 180 140 220 100 160 5 160 250 200 270 140 240 5 2...

Page 11: ...11 20 30 5 3 5 4...

Page 12: ...12 5 6 6 1 6 2 TEKHMANN 6 2 6 2 1 6 2 2 6 2 3...

Page 13: ...13 TEKHMANN 6 3 6 3 1 6 6 3 2 TEKHMANN 1 TEKHMANN 7 7 1...

Page 14: ...14 7 2 4 25 40 1 220 15 10 4 4 25 4 25 80 1 8 8 1 3 8 2 5 40 80 8 3 9...

Page 15: ...15 9 1 12 03039 14 7 32 044 369 57 00 056 375 43 22 9 2 TEKHMANN 9 3 TEKHMANN 1 38 056 375 43 22 9 4 10 TWI 200 B 5...

Page 16: ...250 50 60 20 200 10 65 20 8 25 6 60 VRD 24 5 85 cos 0 9 1 6 4 0 IP21S F 2 9 3 5 12 03039 14 7 32 044 369 57 00 056 375 43 21 22 3 10 10 5 40 80 1 056 375 43 22 TEKHMANN 11 TWI 200 B 6 6 TWI 200 B 1 1...

Page 17: ...TEKHMANN TEKHMANN TEKHMANN TEKHMANN 14 7 32 044 369 57 00 056 375 43 21 22 1 056 375 43 22 9 044 369 57 02 238 032 242 41 75 032 242 41 76 138 7 0472 32 72 12 067 588 90 35 69 1 067 622 33 51 56 067 4...

Page 18: ...he cord Never carry the tool by the cord or yank it to disconnect it from the receptacle Keep the cord away from heat oil and sharp edges 12 Secure work Use clamps or a vise to hold the work It is saf...

Page 19: ...ter system also allows reducing size of the transformer and reactance Such reduction of volume and weight improves mobility and increases performance Welding inverters poses other advantages as arc st...

Page 20: ...t weight Gross weight 2 9 kg 3 5 kg Operating cycle shows the period within which the machine can generate corresponding current It is expressed in based on 10 minutes per cycle e g 65 6 minutes and 3...

Page 21: ...for welding operations Adjust welding current according to diameter of used electrode and according to type of welding seam Below is the table of admissible current according to diameter of the elect...

Page 22: ...performing overhead welding use adequate head wear which will protect your head and neck It is recommended to wear closed safety boots with steel toe caps Maintenance WARNING Before disassembling any...

Page 23: ...service life the product accessories and packaging should be submitted for environmentally clean disposal recycling of waste to the enterprises that meet the criteria of environmental safety ATTENTIO...

Page 24: ...24 TWI 200 B 11 1 TWI 200 B 220 2 2 2 1 2 1 1 2 1 2 2 1 3 2 1 4...

Page 25: ...25 2 1 5 2 1 6 2 1 7 2 1 8 2 1 9 2 1 10 2 1 11 2 1 12 2 1 13 2 1 14 2 1 15 2 1 16 2 1 17 2 1 18 2 1 19 2 1 20 2 1 21 2 1 22 2 1 23 TEKHMANN 2 1 24 TEKHMANN 2 2...

Page 26: ...26 2 2 1 10 2 2 2 5 40 2 3 3 1 3 1 1 TWI 200 B 220 3 1 2 5 40 80 3 1 3 I 160 250 50 60 3 1 4...

Page 27: ...27 3 2 TWI 200 B 1 1 5800 160 250 50 60 20 200 10 65 20 8 25 6 60 VRD 24 5 85 cos 0 9 1 6 4 0 IP21S F 2 9 3 5 3 10 65 6 30 3 30 VRD 24 5 3 3 TWI 200 B 1 1...

Page 28: ...28 1 2 3 4 5 6 3 4 3 4 1 IGBT 50 30 3 4 2 Hot start Arc force Anti stick 3 4 3 5 3 4 4 4 3 4 5 QC IGBT 3 4 6 3 3 4 7...

Page 29: ...29 4 2 4 1 2 4 2 4 3 2 2 2 16 140 16 10 16 160 25 10 16 25 180 36 16 25 200 36 16 20...

Page 30: ...30 25 250 36 20 25 36 300 36 25 4 4 1 1 2 1 5 4 5 3 6 2 5 5 1...

Page 31: ...31 3 1 6 30 55 50 75 20 45 2 40 70 60 100 30 60 2 5 50 100 70 120 40 80 3 2 80 140 110 160 70 130 4 120 180 140 220 100 160 5 160 250 200 270 140 240 5 2...

Page 32: ...32 20 30 5 3...

Page 33: ...33 5 4 5 6 6 1 6 2 TEKHMANN 6 2 6 2 1 6 2 2...

Page 34: ...34 6 2 3 TEKHMANN 6 3 6 3 1 6 6 3 2 TEKHMANN 1 TEKHMANN 7 7 1...

Page 35: ...35 7 2 4 25 40 1 220 15 10 4 4 25 4 25 80 1 8 8 1 3...

Page 36: ...36 8 2 5 40 80 8 3 9 9 1 12 03039 14 7 32 044 369 57 00 056 375 43 22 9 2 TEKHMANN 9 3 TEKHMANN 1 38 056 375 43 22 9 4...

Page 37: ...TWI 200 B 5 5 5800 160 250 50 60 20 200 10 65 20 8 25 6 60 VRD 24 5 85 cos 0 9 1 6 4 0 IP21S F 2 9 3 5 12 03039 14 7 32 044 369 57 00 056 375 43 22 3 10 10 5 40 80 1 056 375 43 22 TEKHMANN 11 TWI 200...

Page 38: ...38 TWI 200 B 1 1 1 1 1 1 1 1 12 TEKHMANN TEKHMANN TEKHMANN...

Page 39: ...39 TEKHMANN 14 7 32 044 369 57 00 056 375 43 21 22 1 056 375 43 22 9 044 369 57 02 238 032 242 41 75 032 242 41 76 138 7 0472 32 72 12 067 588 90 35 69 1 067 622 33 51 56 067 411 90 85...

Page 40: ...40...

Reviews: