ADJUSTMENTS AND CONVERSIONS
Always disconnect the appliance from the
electricity main before making any
adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
11) TAPS
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob
to the “Reduced rate” position (small flame
fig. 1).
- Remove knob “M” (fig. 12 and 12/A) of the tap,
which is simply pressed on to its rod. The by-
pass for minimal rate regulation can be: beside
the tap (fig. 12) or inside the shaft. In any case,
to access to regulation, it can be done trought
the insertion of a small screwdriver ‘’D’’ beside
the tap (fig. 12) or in the hole ‘’C’’ inside the shaft
of the tap (fig 12/A). Turn the throttle screw to the
right or left until the burner flame has been
adequately regulated to the “Reduced rate”
position.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-
assemble the several components.
It is understood that only burners operating
with G20 gas should be subjected to the above
mentioned adjustments. The screw must be
fully locked when the burners operate with G30
or G31 gas (turn clockwise).
12) REPLACING THE INJECTORS
The burners can be adapted to different types of gas by
installing injectors suited to the type of gas required. To
do this, first remove the burner tops using a wrench “B”.
Now unscrew injector “A” (see fig. 13) and fit a injector
corresponding to the type of gas required.
It is advisable to tighten the injector in place.
After the injectors have been replaced, the burners
must be regulated as explained in paragraphs 11.
The technician must reset any seals on the
regulating or pre-regulating devices and affix the
label corresponding to the new gas regulation on
the appliance instead of the already existing one.
This label is supplied in the packet containing the
spare injectors.
The envelope with the injectors and the labels can
be included in the kit, or at disposal to the
authorized Customer Care Department.
For the sake of convenience, the nominal rate chart also
lists the heat inputs of the burners, the diameter of the
injectors and the working pressures of the various types
of gas.
TAPS LUBRIFICATION
Should a tap being blocked,
do not force and ask for
Technical Assistance.
25
Summary of Contents for 40212001
Page 42: ...42 8 8...
Page 44: ...2 7 A A 3 0 1 2 3 4 5 6 44...
Page 45: ...45 30 1 B 4 A B C 6 A 6 B T 6 B AC TC 6 A 6 spray T 6 A A B C 6 A 6 B...
Page 46: ...B 5 f mm 7 7 8 3 6 E 9 9 A 9 S H F S 10 70 mm top 7 46...
Page 47: ...90 C 150 C 7 20 m3 100 cm2 3 200 cm2 8 4 5 9 EN 10226 2 2 EN 10226 CE 2009 142 47...
Page 48: ...10 C 11 11 L N 90 C EMC LVD RoHS ERP 48...
Page 49: ...11 1 M 12 12 A by pass 12 D 12 C 12 A by pass G20 G30 G31 12 13 11 49...
Page 53: ...53 2002 96 EC WEEE...
Page 65: ...65 DADOS T CNICOS DA REGULA O DE G S DO APARELHO...
Page 68: ...68...