INSTALLATION
10) ELECTRICAL CONNECTION
The electrical connections of the appliance
must be carried out in compliance with the
provisions and standards in force.
Before connecting the appliance, check that:
- the voltage matches the value shown on the
specification plate and the section of the wires of
the electrical system can support the load, which
is also indicated on the specification plate.
- The electrical capacity of the mains supply and
current sockets suit the maximum power rating of
the appliance (consult the data label applied to
the underside of the cooktop).
- The socket or system has an efficient earth
connection in compliance with the provisions and
standards in force. The manufacturer declines all
responsibility for failing to comply with these
provisions.
When the appliance is connected to the
electricity main by a socket:
- apply to the input cable “C”, if unprovided
(see fig. 11) a normalized plug adequate to the
load indicated in the identification label. Connect
the cables according to the scheme of fig. 11,
making sure to respect the undermentioned
respondences:
Letter L (live) = brown wire;
Letter N (neutral) = blue wire;
Earth symbol
= green - yellow wire.
- The power supply cable must be positioned so
that no part of it is able to reach an temperature
of 90 °C.
- Never use reductions, adapters of shunts for
connection since these could create false
contacts and lead to dangerous overheating.
- The outlet must be accessible after the built-in.
When the appliance is connected straight to
the electricity main:
- install an omnipolar circuit-breaker between the
appliance and the electricity main. This circuit-
breaker should be sized according to the load
rating of the appliance and possess a minimum
3 mm gap between its contacts.
- Remember that the earth wire must not be
interrupted by the circuit-breaker.
- The electrical connection may also be protected
by a high sensitivity differential circuit- breaker.
You are strongly advised to fix the relative yellow-
green earth wire to an efficient earthing system.
Before performing any service on the electrical
part of the appliance, it must absolutely be
disconnected from the electrical network.
WARNINGS:
all our products are conform with the
European Norms and relative amendments.
The product is therefore conform with the
requirements of the European Directivesin
force relating to:
- compatibility electromagnetic (EMC);
- electrical security (LVD);
- restriction of use of certain hazardous
substances (RoHS);
- EcoDesign (ERP).
IMPORTANT: the appliance must be installed
following the manufacturer's instructions.
The manufacturer will not be liable for injury
to persons or animals or property damage
caused by an incorrect installation.
If the installation requires modifications to
the home's electrical system or if the socket
is incompatible with the appliance's plug,
have changes or replacements performed by
professionally-qualified person. In particular,
this person must also make sure that the
section of the wires of the socket is suitable
for the power absorbed by the appliance.
Summary of Contents for 40212001
Page 42: ...42 8 8...
Page 44: ...2 7 A A 3 0 1 2 3 4 5 6 44...
Page 45: ...45 30 1 B 4 A B C 6 A 6 B T 6 B AC TC 6 A 6 spray T 6 A A B C 6 A 6 B...
Page 46: ...B 5 f mm 7 7 8 3 6 E 9 9 A 9 S H F S 10 70 mm top 7 46...
Page 47: ...90 C 150 C 7 20 m3 100 cm2 3 200 cm2 8 4 5 9 EN 10226 2 2 EN 10226 CE 2009 142 47...
Page 48: ...10 C 11 11 L N 90 C EMC LVD RoHS ERP 48...
Page 49: ...11 1 M 12 12 A by pass 12 D 12 C 12 A by pass G20 G30 G31 12 13 11 49...
Page 53: ...53 2002 96 EC WEEE...
Page 65: ...65 DADOS T CNICOS DA REGULA O DE G S DO APARELHO...
Page 68: ...68...