IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
8-14-17
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
REFERENCE NUMBER
INS-2621-00
1.
Mount fixture onto suitable enclosure according
to designed lighting plan. Use locknut to secure.
2. Make watertight connections from remote
transformer to fixture leads using waterproof
wire connectors (By Others).
See wiring
diagram.
Standard Fixture Installation
Aiming
1. To aim vertically, loosen the lamp head adjustment
screw using a 5/32” Allen wrench, adjust as needed,
then secure aiming position by tightening lamp
head adjustment screw.
Do not rotate more than 360 degrees to avoid
wire damage.
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
WIRING DIAGRAM
Transformer
COM
GROUND
WIRING DIAGRAM
PINNACLE FLOODLIGHT™ (PNF)
Must install to a suitable enclosure. Recommended for use with Power Pipe™ or
Pillar Mount Canopy (PMC).
LED - For use with 12VAC
remote transformer or magnetic
transformers only. Teka Illumination
cannot guarantee performance with third
party manufacturers’ transformers.