IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
WIRING DIAGRAM
Transformer
COM
GROUND
120V
12V
Fixture
COM
Remote
Transformer
COM
120V
12V
Fixture
COM
GROUND
WIRING DIAGRAM
Transformer
COM
GROUND
2. Install Universal Mounting Ring™.
6. Make watertight connections using waterproof
wire connectors to connect secondary side of
transformer in junction box with fixture leads.
See wiring diagram.
DATE
5-4-17
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
REFERENCE NUMBER
INS-2552-00
Phase 2 - Fixture Installation
WIRING DIAGRAM
3. Temporarily attach mounting plate to universal
mounting ring using two (2) screws in final
mounting position with Phillips screwdriver.
4. Using holes on mounting plate as a guide,
market location of 1/4” fasteners to be used to
anchor mounting plate securely to wall.
Dimensions will vary with size of fixture.
1. Make watertight connections using waterproof
wire connectors (By Others) to connect
primary branch circuit wiring to primary side of
transformer. Place transformer into junction box.
See wiring diagram.
5. Remove mounting plate, then drill holes into
surface as per marked locations for 1/4” fasteners.
(Fasteners by Others). Use suitable mounting
hardware (By Others) for mounting surface.
ARCADE SERIES™ (AR)
Phase 1 - Rough In
Installation of Back box
1. Install Conduit (By Others) to be used with
this product.
2. Install junction box (By Others) so that front
face is flush with finished wall.
3. Connect box to conduit and pull wires for
connections (See wiring diagram).
Additional Info
• Please follow National and Local electrical codes for your area.
• Use 4” round cast box
• Suitable for through wire
• Suitable for installation into combustible materials.
• Rated for 90° C.
• Junction box, universal mounting ring screws, box mounting hardware
and gaskets (By Others)
AR Series not intended for base down mounting.
Junction box must be secured to a structural member suitable for
weight of the luminaire and other weight likely to be placed upon it.
IMPORTANT! Orientation of universal
mounting ring determines fixture orientation.
WIRING DIAGRAM