background image

 

 

 

  

 

Philips Lighting North America Corporation 
200 Franklin Square Drive 
Somerset, NJ  08873, USA 
Phone:  855-486-2216 

www.philips.com/luminaires

  

Philips Lighting Canada Ltd. 
281 Hillmount Road, 
Markham, ON, Canada  L6C 2S3 
Phone:  800-668-9008 

www.philips.com/luminaires

 

9140053342  February 2016 

 

          

 

 

TMFIC/ZMFIC Series 

 

200W-450W Emergency 

Luminaire 

 

 

INSTALLATION AND 

OPERATING 

INSTRUCTIONS 

 

IMPORTANT 

SAFEGUARDS 

 
When  using  electrical  equipment,  basic  safety 
precautions  should  always  be  followed,  including 
the following: 

 

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS 

 

All  servicing  should  be  performed  by  qualified 
personnel only. 
 
Equipment  should  be  mounted  in  locations  and  at 
heights  where  it  will  not  be  readily  subjected  to 
tampering by unauthorized personnel. 
 
The  use  of  accessory  equipment  not  recommended 
by the manufacturer may cause an unsafe condition. 
 
Do  not  use  this  equipment  for  other  than  intended 
use. 
 
Do not use outdoors. 
 
Do not let supply cords touch hot surfaces. 
 
Do not mount near gas or electric heaters. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CAUTION:    Halogen  cycle  lamp(s)  are  used  in 
this  equipment.    To  avoid  shattering:    Do  not 
operate  lamp  in  excess  of  rated  voltage,  protect 
lamp against abrasion and scratches and against 
liquids  when  lamp  is  operating,  dispose  of  lamp 
with care. 

 
Halogen  cycle  lamps  operate  at  high  temperatures.  
Do  not  store  or  place  flammable  materials  near 
lamp. 
 
CAUTION:    “To  avoid  electrical  overload,  total 
connected  lamp  load  (factory  and  field  installed) 
should not exceed output rating”. 
 

SAVE THESE 

INSTRUCTIONS 

WARNING  –  Shut  off  AC  power  to  branch 
circuits  to  which  units  will  be  connected.    All 
wiring  should  be  per  N.E.C.  Articles  501-4(b) 
and local codes. 
 
To  maintain  warranty,  equipment  with  batteries 
must  be  installed  or  placed  on  charge  within 
prescribed period after shipment. 

Summary of Contents for TMFIC Series

Page 1: ...recommended by the manufacturer may cause an unsafe condition Do not use this equipment for other than intended use Do not use outdoors Do not let supply cords touch hot surfaces Do not mount near gas or electric heaters CAUTION Halogen cycle lamp s are used in this equipment To avoid shattering Do not operate lamp in excess of rated voltage protect lamp against abrasion and scratches and against ...

Page 2: ...ole of housing in preparation for unit wiring For surface conduit wiring there are a total of six knockouts which can be used for service entrance and exit Figure 1 OPTIONAL MOUNTING SHELF FOR COLUMN POLE OR I BEAM 1 If the unit is to be mounted to poles columns or I Beams use the optional mounting shelf kit and strapping kit ordered separately 2 If mounting shelf is to be used for wall mounting t...

Page 3: ...TE LOADS WITH LOAD CONNECTION JUMPERS INSTALLED SMALLER REMOTE LOAD REQUIREMENTS 1 When using the jumpers simply subtract the internal lamp total wattage from the unit total wattage and the remainder is the available total remote load capacity Balancing of RL1 and RL2 is not required as the jumpers perform the remote load balancing 2 When figuring total load include the wattage of the internal lam...

Page 4: ... internal lamp 1 and internal lamp 3 are on the RL1 fused circuit Internal lamp 2 is connected to the RL2 fused circuit For RL1 circuit subtract twice the internal lamp rating from half the unit wattage and the remainder is the available remote load capacity For RL2 circuit subtract one internal lamp wattage from half the unit wattage and the remainder is the RL2 remote capacity Example A 300 watt...

Page 5: ...ally initiated diagnostic test Red LED indicator Single Flash battery fault Two Flashes lamp failure light bar failure EXIT signs Three Flashes charger fault Four Flashes transfer fault If more than one fault condition is present simultaneously the red LED will flash the indication pattern for each fault independently then repeat the cycle Pushbutton Test Switch Long Press longer than 0 5sec trans...

Page 6: ...ion 200 Franklin Square Drive Somerset NJ 08873 USA Phone 855 486 2216 www philips com luminaires Philips Lighting Canada Ltd 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 www philips com luminaires 9140053342 February 2016 ...

Page 7: ...NJ 08873 USA Phone 855 486 2216 www philips com luminaires Philips Lighting Canada Ltd 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 www philips com luminaires 9140053342 February 2016 BATTERY HOOKUP DIAGRAMS 12V 200W 12V 250W 12V 300W 24V 300W 12V 450W 24V 450W ...