meter.
3.3.2
Right / Reset Button
•
Press the
Right
-arrow button to reset the maximum or minimum value while it is being displayed
(see
Up / Display Button
below).
•
Press the
Right
-arrow button to move to the next digit or decimal position during programming.
•
Press
Right
to go backward through most selection menus.
3.3.3
Up / Display Button
•
Press Display when in
Run Mode
to cycle through displaying the maximum value, minimum
value, and the loop input value in mA. The display will time out in 12 seconds. Press Display
again to resume normal lower display oper- ation (lower display will read RESUME).
•
Press the
Up
-arrow button to scroll forward through the menus, decimal point, or to increment
the value of a digit.
3.3.4
Enter Button
•
Press the
Enter
button to access a menu or to accept a setting.
•
Press
Enter
to acknowledge alarm (if enabled).
3.4
Main Menu
The main menu consists of the most commonly used functions:
Setup, Advanced,
and
Password.
Press
MENU
button to enter
Programming Mode
then press the
Up
-arrow button to scroll
through the main menu.