background image

Tube cleaning system

pro

tub

23-24

Año

Year

TEINNOVA reserves the right to make changes to the equipment without prior notice.

TECAI INNOVA S.L.
C/ Las Balsas 16-B, Pol. Ind. Cantabria.
26009 LOGROÑO (La Rioja), Spain.

guarantee conditions

1. 

“TEINNOVA” guarantees its products for a period of 

15 days as regards aesthetic defects or faults which are 
noticeable with the naked eye. In terms of all other
manufacturing defects and faults in the products, the
guarantee is of 1 year. 
The “Buyer” must notify “TEINNOVA” of the existence 
of any defects as soon as they are observed and in any 
case within a maximum deadline of 5 days from when 
they become apparent. Notification thereof outside of 
said deadline shall lead to the non-application of the 
guarantee.
“TEINNOVA” reserves the right to request that the
products be sent to the factory or the closest official
Technical Support Service for their due inspection and 
the delivery costs are payable by the “Buyer”. Said costs 
shall be reimbursed if the product is proven to be
effectively non-conforming.
“TEINNOVA” will pick up and send the products to the 
factory or to the nearest official Technical Assistance
Service for proper inspection. At that time, it will be
determined whether the warranty will apply or it is within 
the warranty exclusions. If the guarantee is applicable, 
the transport, both collection at the customer’s facilities 
and return of the product, will be borne by TEINNOVA. 
If it is excluded from guarantee (point 2), the transport, 
both collection at the customer’s facilities and return of the 
product, will be borne by the customer.
“TEINNOVA” reserves the right to overrule the
application of the guarantee when there is no evidence 
of the product’s non-conformity and it shall not apply said 

guarantee until coverage has been expressly proven.
In the case that the product is covered, “TEINNOVA” can 
replace it or determine the necessary repair method.
All repair works that are carried out under the product 
guarantee must be carried out in “TEINNOVA”
facilities or in those of the party it designates.
The guarantee covers the materials and labour
required to repair or replace the parts or elements
considered as defective from origin. The maximum 
guaranteed amount or value shall be the maximum
price of the sale of the product to the “Buyer”.
Any claims made under the coverage of the guarantee 
shall not grant the right to delay and/or withhold
payment of the corresponding invoice and/or any 
other pending invoices.

2.

 Guarantee Exclusions: the following are excluded 

from the guarantee: actions, alterations or
manipulations of the product that are carried out
without the prior express authorisation of the “Seller”; 
indirect and/or consequential damage; damage
caused by negligence, by improper use or by usage 
that does not conform to the instructions and intentional 
damage; faults due to adaptations made to the
products or the use of parts that were not
previously and expressly certified or authorised by the 
Seller; costs for detection of the fault; costs for
collection or replacement (the latter two are unless the 
non-conformity is proven and within the limits
established in section 1).

Summary of Contents for TECAi protub

Page 1: ...user manual EN protub Tube cleaning system Original manual translation...

Page 2: ...ur strategy We offer the option of providing companies with specific training in the use of our equipment and to educate their operators so they perform the best service and thus contribute to the suc...

Page 3: ...24 contents symbols used safety warnings conditions of use know your machine control panel accessories and related equipment operating instructions transport maintenance and care 5 24 6 24 7 24 8 24...

Page 4: ...Tube cleaning system protub 4 24 contents waste management troubleshooting guide technical specifications guarantee conditions declaration of conformity CE 20 24 21 24 22 24 23 24 24 24...

Page 5: ...tructions given are not followed properly Make sure you read all the instructions in the Safety information section WARNING This symbol warns you of a potentially dangerous situation that could result...

Page 6: ...ys hold the flexible rotor shaft firmly while using the brush Safety glasses must always be worn to prevent any possible spray or splashes from reaching the operator s eyes Fasten your PROTUB properly...

Page 7: ...in heat exchangers both Fire tube and Water tube down to a minimum diameter of 14 mm and for cleaning ventilation or air conditioning ducts up to a maximum diameter of 400 mm Suitable accessories mus...

Page 8: ...exible rotor shaft connection 4 Anti vibration supports 5 Mains power connection 6 Water tight electrical connection cover 7 Remote control compartment 8 Water supply connection 9 Cooling grille 10 Em...

Page 9: ...d Display Immediately stops the electric motor Pressing on this icon causes the rotation speed to increase while it remains pressed Pressing on this icon causes the rotation speed to decrease while it...

Page 10: ...rushes Code 999332003 Protub shaft spanners An 8 meter long 1 5 mm cross section cable the electrical connection at the machine uses a PROTUB specific power supply connector The connection to the main...

Page 11: ...ement of your PROTUB 1 operating instructions Put your PROTUB in its working position on a flat and stable surface as shown in the image Fit the chosen flexible rotor shaft to carry out the work as sh...

Page 12: ...rections of rotation shown in the figure The flexible rotor shaft head of your PROTUB is designed to allow special brushes to be fitted which allow you to work more efficiently and comfortably These b...

Page 13: ...ction to your PROTUB is done by turning the blue connector clockwise as shown in the figure Connection to mains power 4 Connect the hose to a water supply with a minimum pressure of 2 bar There are ad...

Page 14: ...ion can be started using the pneumatic pedal If you want to increase the rotation speed of the electric motor press the Increase rotation speed button This button is shown in the figure The value will...

Page 15: ...ting from the machine 7 To select the direction of spin you want the brush to use and to start the brush rotating turn the selector so that it matches the icon shown To select the direction of spin yo...

Page 16: ...h rotation using the remote control To select the direction of spin you want the brush to use and to start the brush rotating press the button with the icon shown To select the direction of spin you w...

Page 17: ...t it from the the water inlet of your PROTUB as shown in the image Disconnect you PROTUB from the electrical supply This is done with a counter clockwise turn of the blue connector as shown in the fig...

Page 18: ...be placed in its normal working position vertical and the brakes on the front wheels activated It is not advisable to place the machine on a pallet or similar The machine must be on a completely flat...

Page 19: ...ding it Keep connections clean to avoid clogged pipes that could cause serious damage to the main components of the machine maintenance and care TEINNOVA stocks spare parts for all the machine s compo...

Page 20: ...for recycling Do not dispose of electrical equipment in the trash We recommend that electrical tools and accessories are subjected to an environmentally friendly recovery process Please dispose of th...

Page 21: ...adius of curvature Contact Tecai Innova S L Technical Services Page 24 Flexible shaft broken at the chassis end Mechanical failure of the connection of the flexible shaft to the drive system Contact T...

Page 22: ...on Control system Sizes Weight Flexible rotor shaft length Structural material 1 HP 0 900 rpm 70 dB Clockwise Anti clockwise Electrical 215 x 357 x 393 mm 14 kg 31 lbs 10 and 15 metres Stainless steel...

Page 23: ...transport both collection at the customer s facilities and return of the product will be borne by the customer TEINNOVA reserves the right to overrule the application of the guarantee when there is n...

Page 24: ...scribed above complies with all the essential requirements of the following directives Machinery directive 2006 42 CE Directive 2014 30 EU on electromagnetic compatibility and its amendments Directive...

Reviews: