Table 2-3. NC-Series Electrical Data 60 hz (Oil Filled)
Motor Size
Start KVA
Full Load KW Full Load BHP
Full & No Load
Current at
230 Volts
Full & No Load
Current at
460 Volts
Full & No Load
Current at
575 Volts
Max Process
Fluid Temp (˚F)
at Full Load
N1
31.1
6.9
6.8
20.8 / 7.2
10.4 / 3.6
8.3 / 2.9
300
N2
47.2
13.4
13.5
39.2 / 9.8
19.6 / 4.9
15.7 / 3.9
300
N3
89.2
21.7
23.0
63.0 / 16.8
31.5 / 8.4
25.2 / 6.7
280
N4
119.5
30.9
32.3
88.0 / 24.0
44.0 / 12.0
35.2 / 9.6
260
N5
227.1
48.0
50.8
133.8 / 35.0
66.9 / 17.5
53.5 / 14.0
290
N6
283.3
85.9
87.4
259.6 / 36.8
129.8 / 18.4
103.8 / 14.7
265
N7
344.7
107.3
104.8
311.6 / 66.0
155.8 / 33.0
124.6 / 26.4
250
N8
729.0
150.2
154.8
416.0 / 111.8
208.0 / 55.9
166.4 / 44.8
245
NL1
15.8
3.3
3.4
11.0 / 6.0
5.5 / 3.0
4.4 / 2.4
300
NL2
23.5
6.3
6.4
21.0 / 7.6
10.5 / 3.8
8.4 / 3.0
300
NL3
37.4
10.2
11.5
33.6 / 19.8
16.8 / 9.9
13.4 / 7.9
280
NL4
69.0
13.0
14.1
43.0 / 16.4
21.5 / 8.2
17.2 / 6.6
260
NL5
72.8
23.9
25.4
75.2 / 22.2
37.6 / 11.1
30.1 / 8.9
290
Table 2-4. NC-Series Electrical Data 60 hz (Dry)
Motor Size
Start KVA
Full Load KW Full Load BHP
Full & No Load
Current at
230 Volts
Full & No Load
Current at
460 Volts
Full & No Load
Current at
575 Volts
Max Process
Fluid Temp (˚F)
at Full Load
N1
31.1
7
6.8
20.8 / 7.2
10.4 / 3.6
8.3 / 2.9
300
N2
47.2
9.3
9.5
27.6 / 9.8
13.8 / 4.9
11.0 / 3.9
290
N3
89.2
15.4
16.1
45.0 / 16.8
22.5 / 8.4
18.0 / 6.7
290
N4
119.5
20.2
20.8
57.4 / 24.0
28.7 / 12.0
23.0 / 9.6
275
N5
227.1
37
37
95.0 / 35.0
33.6 / 17.5
38.0 / 14.0
280
N6
283.3
62
56.5
173.0 / 36.8
86.5 / 18.4
69.2 / 14.7
260
N7
344.2
76
68.4
216.0 / 66.0
108.4 / 33.0
86.7 / 26.4
245
N8
729.0
96.5
88
266.0 / 111.8
133.0 / 55.9
106.4 / 44.8
250
NL1
15.8
3.5
3.4
11.0 / 6.0
5.5 / 3.0
4.4 / 2.4
300
NL2
23.5
4.7
4.7
15.2 / 7.6
7.6 / 3.8
6.1 / 3.0
300
NL3
37.4
7.9
8.1
24.2 / 19.8
12.1 / 9.9
9.7 / 7.9
280
NL4
69.0
9.5
10.4
28.0 / 16.4
14 / 8.2
11.2 / 6.6
260
NL5
72.8
17.5
18.5
48.8 / 22.2
24.4 / 11.1
19.5 / 8.9
290
NOTES:
1.)
SELECT CLASS 10 HEATERS BASED ON START KVA WITH A 12 SECOND MAX TRIP TIME.
2.)
( ) INDICATES REDUCTION IN SWITCH SIZE WHEN DUAL-ELEMENT FUSES ARE USED FOR MOTOR BRANCH CIRCUITS.
3.)
(EXCEPT WHERE NOTED), THE SWITCH SIZES ARE THE SAME FOR ALL TYPES OF FUSES.
4.)
CURRENT RATINGS BASED ON THREE CONDUCTOR 75O C INSULATED COPPER WIRE AT 30O C AMBIENT.
5.)
INDUCTION MOTOR, SYNCHRONOUS SPEED 3600 RPM.