F- THINGS THAT MUST BE DONE BEFORE CALLING AUTHORIZED
SERVICE
25
CAUTION!
•
•
•
Troubleshooting
Possible Solution
Result.
Cooler is NOTE working. (No sound
or only fan sound comes from the
product.)
It may be due to the thermostat
NOTE plugged in. The fuse may be
blown or broken down.
Condenser lamella may be ob-
structed or get dirty.
It will run again when reached to
the suitable temperature.
Insert the plug properly.
Consult to an Authorized Tefcold
Ser vice or a competent electrician.
Clean the condenser lamellas.
Device internal temperature is high.
External ambient temperature is
very high or wrong thermostat
setting.
Very close to the back wall, ventila-
tion shutters are obstructed or it’s
front is prevented.
It may have been expose to exces-
sive external wind.
Condenser lamellas are very dirty.
Move the cooler to a place where
the external temperature is lower.
Adjust to the stated gap.
Clean in front of the ventilation
shutters.
Prevent the wind.
Clean the condenser lamellas.
Device internal temperature is very
low.
Wrong internal thermostat setting.
Re-set the thermostat.
High degree of sweating on the
glass and inside the device.
Water discharge hole may be
obstructed when sweating is seen
inside the cabin.
In glass sweating on the other hand,
current external ambient humidity
is over 65%.
Clean water discharge hole. With re-
gards to the high humidity, you can
move your cooler to an environment
with less humidity.
Bad smell coming from the bottom
part of the cooler.
Lower water discharge tray is dirty.
Clean the water discharge tray.
Summary of Contents for UFFS 45
Page 1: ...TEFCOLD COMMERCIAL TYPE VERTICAL FROZENFOOD STORAGE CABINET OPERATING MANUAL...
Page 2: ......
Page 4: ......
Page 19: ...D USINGYOUR PRODUCT 16 WARNING PICTURE 11 PICTURE 12 PICTURE 13 Start up...
Page 24: ...D USINGYOUR PRODUCT 21 Your product has manual defrost...
Page 31: ......
Page 32: ......