background image

Maintenance (Continued)

10. Pull lip ring of bladder through tank

opening and seat it against tank
head.

11. Clean sealing surface and groove of

cover flange; place on tank (See
Figure 20).

NOTE:

Be sure elbow lines up with hole

in base.

12. Tighten nuts as follows:

a. Hand tighten all nuts.

b. Tighten one nut snug.

c. Tighten opposite nut snug.

d. Proceed, tightening opposite pairs

of nuts to a snug fit.

e. Recheck all nuts, using same

pattern. Be sure all nuts are tight
and that you have a good seal.

IMPORTANT:

Do not overtighten; you

may twist studs off of tank. If you have
a torque wrench, tighten to 85 inch-
pounds of torque.

13. Stand tank on feet and reconnect

piping.

14. Recharge tank to proper air

pressure.

15. Prime pump (See Page 9).

TO CHECK TANK AIR CHARGE

If drawdown (amount of water that
comes out of tank per pump cycle)
decreases significantly, check as follows:

1. To check air charge in tank, shut OFF

electric power to pump, open faucet
near tank, and drain completely.

2. At the air valve in top of tank, check

air pressure with a standard tire
gauge. Air pressure should be 2 psi
below pump pressure switch cut-in
setting.

3. If the air pressure is more than 2 psi

below the cut-in setting, add air to
the tank. Use an air compressor or a
portable air storage tank.

4. Use soap or liquid detergent to check

for air leaks around air valve.
Continuous bubbling indicates a leak.
If necessary, install new core in air
valve. This is the same as those used
for automobile tubeless tires.

HOW TO HANDLE A GASEOUS WELL

If well water contains gases, suspend a
pipe, closed at the bottom and open at
the top, so that it surrounds the suction
pipe inlet (See Figure 28). Since the
gases rise in the well casing, the water
sucked down through the pipe and into
pump suction is gas-free. This type of
well must be vented to the outside of
any enclosure.

14

Teel Operating Instructions and Parts Manual

3P683D, 3P684D, 2P899A and 3P715B

Teel Standard Shallow Well 
Jet Pumps and Systems

®

E

N
G

L

I

S

H

Water
Cell

Tank 
Wall

Cover 
Flange

Figure 27 – Proper Installation And
Seating

Not

to

Scale

Pipe strap or
wire to hold
pipe sleeve

Pipe
sleeve

Pipe
cap

Tail
pipe

Foot
valve

2369 0396

Gases
rise to 
surface

Figure 28 – Sleeve installation for
gaseous well

Water
cell

Tank
wall

Cover
flange

Not

to

Scale

Summary of Contents for 2P899A

Page 1: ...a 6 gallon pre charged tank equal to a fifteen gallon standard tank Used with drilled cased driven point or dug wells or in cisterns or lakes Comes assembled to save on installation Equipped with a 11...

Page 2: ...ound motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connect...

Page 3: ...cept as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions...

Page 4: ...ould be at least as large as the suction port on the pump include a check valve See Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so th...

Page 5: ...est possible fittings especially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe See Figure 3 Make sure...

Page 6: ...ove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port See Figure 5 Run tubing from the pump s AVC port See Figure 5 to the port on the AVC mounted on the tank See instructions provided w...

Page 7: ...Manual E N G L I S H Figure 7 Motor wiring connections through Pressure Switch Match motor voltage to line voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connect...

Page 8: ...authority NOTE If you are connecting the motor to a 230 volt circuit using a four conductor cable connect both the neutral white and ground green to the ground terminal The other two wires two black w...

Page 9: ...Run the pump through one or two complete cycles to verify correct operation This will also help clean the system of dirt and scale dislodged during installation Maintenance Pump and piping need not b...

Page 10: ...haft flats and unscrew impeller by turning counterclockwise when looking into eye of impeller 5 To reinstall reverse steps 1 through 4 Mount diffuser as shown in Figure 20 6 See directions under Pump...

Page 11: ...seat correctly after recleaning cavity place a cardboard washer over polished seal face and carefully press into place using a piece of standard 3 4 pipe as a press IMPORTANT Be sure you do not scrat...

Page 12: ...8 washer pull heat sink into cavity See Figure 22 5 Clean out any surplus Permatex from insert cavity where new seal will be located Figure 23 6 Follow steps 2 through 11 under Installing New Seal PU...

Page 13: ...nnect power to pump 2 Follow steps 2 through 5 under Testing For Bladder Leakage above 3 Remove nuts from tank cover flange Tap cover flange to break seal and remove 4 Bladder will not come out in one...

Page 14: ...tire gauge Air pressure should be 2 psi below pump pressure switch cut in setting 3 If the air pressure is more than 2 psi below the cut in setting add air to the tank Use an air compressor or a porta...

Page 15: ...ed Pipe plug 1 14 1 4 NPT w TFE Barbed elbow 2 15 Switch tube U37 191P 1 16 Plastic gasket J20 18 1 17 Pump ejector body insert N76 29P 1 18 10 16 Hi Lo Capscrew U30 742SS 4 19 45 Nozzle N34P 19 1 20...

Page 16: ...list Address parts correspondence to Grainger Parts P O Box 3074 1657 Shermer Road Northbrook IL 60065 3074 U S A 1 Tank Assembly Incl Diaphragm Valve Nuts Inlet Flange U231 498 1 2 Inlet Flange Assem...

Page 17: ...er level in a shallow well operation exceeds 25 ft a deep well pump is needed 3 Ejector or impeller is plugged 3 Clean ejector or impeller see maintenance 4 Check or foot valves stuck in closed 4 Repl...

Page 18: ...f necessary add air pressure with an air hose Check air valve for leaks using a soapy solution and replace core if necessary Air spurts from 1 Pump is picking up prime 1 As soon as pump picks up prime...

Reviews: