10. Hold motor shaft with 7/16” open

end wrench on shaft flats and screw
impeller onto shaft. Be sure you do
not touch capacitor terminals with
body or any metal object.
Tightening impeller will auto-
matically locate seal in correct
position.

11. Remount diffuser on seal plate. BE

SURE diffuser is right side up as
follows (Figure 20).

a. Rib next to priming hold should

be at six o’clock position;

b. Part number (N1-28P) should be

between nine o’clock and ten
o’clock;

c. Both mounting screws must

engage screw holes in seal plate
(Figure 20).

d. BE SURE rubber pad (See Figure

20) stays in place on top of
diffuser.

12. Follow instructions under “Pump

Reassembly,” at right.

IMPORTANT:

If the copper heat sink

moves or shifts during seal removal, it
should be removed and reinstalled.

NOTE:

First, follow instructions under

“Pump Disassembly”.

Remove ceramic portion of sink (See
“Removing Old Seal”). Grasp copper
cone  with fingers at the large end and
move back and forth. Be careful not to
deform it.

COPPER HEAT SINK INSTALLATION

1. Clean off all sealant and foreign

material.

2. Clean out heat sink cavity in seal

plate.

3. Apply thin layer of non-hardening

Permatex on outer surface of heat
sink (part that fits into cavity, Figure
21).

4. Using standard 7/8” socket, bolt, and

1

3

8

” washer pull heat sink into cavity

(See Figure 22).

5. Clean out any surplus Permatex from

insert cavity where new seal will be
located (Figure 23).

6. Follow steps 2 through 11 under

“Installing New Seal”.

PUMP REASSEMBLY

1. Install new O-Ring gasket on seal

plate (Figure 29, Ref. Nos. 5 and 3).

2. Pick up a small amount of liquid soap

on one finger and spread evenly over
O-Ring gasket for lubrication during
reassembly. Be careful not to nick or
tear O-Ring.

3. Replace motor onto pump body; be

sure rubber pad stays in place on top
of diffuser. Tighten four hex nuts
and lockwashers snugly (35-45 inch-
lbs. torque). Do not overtighten.

12

Teel Operating Instructions and Parts Manual

3P683D, 3P684D, 2P899A and 3P715B

Teel Standard Shallow Well 
Jet Pumps and Systems

®

E

N
G

L

I

S

H

WIPE ON SMALL AMOUNT OF

NON-HARDENING PERMATEX

ON THIS SURFACE

756 0993

7/8" SOCKET

BOLT

1-3/8" O.D.

WASHER

038 0893

Figure 20 – Locate and Mount Diffuser

Figure 21 – Apply gasket seal

Figure 22 – Pull seal into place

REMOVE
SURPLUS
PERMATEX

PROPERLY
SEATED

039 0893

Figure 23 – Check seating and clean up
any extra gasket sealer.

Seal plate

Diffuser

Priming hole

7/8” Socket

1

3

8

” O.D.

Washer

Remove

surplus

Permatex

Properly

seated

Bolt

Rib at 6 o’clock

Be sure nibs 

engage notches

Molded 

part no. at

9:30 o’clock

Be sure rubber

pad stays in place

on top of diffuser

Be sure screw

engages hole in 

seal plate

Be sure screw

engages hole in 

seal plate

Wipe on small amount of
non-hardening Permatex
on this surface.

Summary of Contents for 2P899A

Page 1: ...a 6 gallon pre charged tank equal to a fifteen gallon standard tank Used with drilled cased driven point or dug wells or in cisterns or lakes Comes assembled to save on installation Equipped with a 11...

Page 2: ...ound motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connect...

Page 3: ...cept as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions...

Page 4: ...ould be at least as large as the suction port on the pump include a check valve See Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so th...

Page 5: ...est possible fittings especially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe See Figure 3 Make sure...

Page 6: ...ove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port See Figure 5 Run tubing from the pump s AVC port See Figure 5 to the port on the AVC mounted on the tank See instructions provided w...

Page 7: ...Manual E N G L I S H Figure 7 Motor wiring connections through Pressure Switch Match motor voltage to line voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connect...

Page 8: ...authority NOTE If you are connecting the motor to a 230 volt circuit using a four conductor cable connect both the neutral white and ground green to the ground terminal The other two wires two black w...

Page 9: ...Run the pump through one or two complete cycles to verify correct operation This will also help clean the system of dirt and scale dislodged during installation Maintenance Pump and piping need not b...

Page 10: ...haft flats and unscrew impeller by turning counterclockwise when looking into eye of impeller 5 To reinstall reverse steps 1 through 4 Mount diffuser as shown in Figure 20 6 See directions under Pump...

Page 11: ...seat correctly after recleaning cavity place a cardboard washer over polished seal face and carefully press into place using a piece of standard 3 4 pipe as a press IMPORTANT Be sure you do not scrat...

Page 12: ...8 washer pull heat sink into cavity See Figure 22 5 Clean out any surplus Permatex from insert cavity where new seal will be located Figure 23 6 Follow steps 2 through 11 under Installing New Seal PU...

Page 13: ...nnect power to pump 2 Follow steps 2 through 5 under Testing For Bladder Leakage above 3 Remove nuts from tank cover flange Tap cover flange to break seal and remove 4 Bladder will not come out in one...

Page 14: ...tire gauge Air pressure should be 2 psi below pump pressure switch cut in setting 3 If the air pressure is more than 2 psi below the cut in setting add air to the tank Use an air compressor or a porta...

Page 15: ...ed Pipe plug 1 14 1 4 NPT w TFE Barbed elbow 2 15 Switch tube U37 191P 1 16 Plastic gasket J20 18 1 17 Pump ejector body insert N76 29P 1 18 10 16 Hi Lo Capscrew U30 742SS 4 19 45 Nozzle N34P 19 1 20...

Page 16: ...list Address parts correspondence to Grainger Parts P O Box 3074 1657 Shermer Road Northbrook IL 60065 3074 U S A 1 Tank Assembly Incl Diaphragm Valve Nuts Inlet Flange U231 498 1 2 Inlet Flange Assem...

Page 17: ...er level in a shallow well operation exceeds 25 ft a deep well pump is needed 3 Ejector or impeller is plugged 3 Clean ejector or impeller see maintenance 4 Check or foot valves stuck in closed 4 Repl...

Page 18: ...f necessary add air pressure with an air hose Check air valve for leaks using a soapy solution and replace core if necessary Air spurts from 1 Pump is picking up prime 1 As soon as pump picks up prime...

Reviews: