background image

 

 

                                                                                   CenterLine 230BP; Müller SPRAYDOS Installation Manual 

  

 

 

 

                                                                                                                     020-041-UK R5

10

 

 

                                                                                   CenterLine 230BP; Müller SPRAYDOS Installation Manual 

  

 

 

 

                                                                                                                     020-041-UK R5

10

+ -

1

1

2

2

1008-0189

15

/3

0

82

31

Be care full when the keypad is mounted in the 

profile again. There is a risk for damaging the 

flex board.

Assemble the controller again and connect the 

system as shown in the system overview draw-

ing.

CONNECTING POS. 11 & 14 TO POWER: 

POS

DESCRIPTION

1

+12V (15/30)

2

Ground (31)

 

The power supply must be strong enough to operate the Sec-

tion and Master valves. The total current will depend on the 

used valve type.

BATTERY CABLE (OPTION):

If a power connector (Socket) isn't available in the tractor cabin, a optional battery cable can be 

used (PN 96ET14).

 

! When connecting the system to 12V 

power it's very important that the polarity 

is correct, if not the system will be dam-

aged.  

 

Summary of Contents for Centerline 230BP

Page 1: ...020 041 UK R5 Installation Manual for M ller SPRAYDOS controller...

Page 2: ...any of the following Disturbance to from any electronic services or products that do not confirm to the standards for CE marking Missing or poor signal coverage or a succession hereof from exter nal...

Page 3: ...lves in automatic mode and the controller section switches should be set to off unless the operator wants to override the auto mode and thus force spraying The Centerline 230BP monitors the controller...

Page 4: ...DOS Installation Manual 020 041 UK R5 4 CenterLine 230BP M ller SPRAYDOS Installation Manual 020 041 UK R5 AUT MATIC B OM SECTION CONTROL 1008 0185 B A B A A B SYSTEM OVERVIEW Note CenterLine 230 is p...

Page 5: ...x 14 Power connector M ller SPRAYDOS 15 Machine connector from Sprayer INSTALLING THE SPRAYDOS ADAPTER CABLE To get electrical contact with the sections and the Master switch in the SPRAYDOS it s nece...

Page 6: ...om of the profile Be care full the wires are just long enough to make it possible to un screw the buzzer from the profile Not all SPRAYDOS controllers has the buzzer fastened as shown some has it plac...

Page 7: ...in the bottom plastic end plate between the power cable gland and the rear edge of the end plate Make a 1 5 mm gab as shown on the picture Place the free wires of the SPRAYDOS adapt er cable one by on...

Page 8: ...4 8 7 Connect the small adapter circuit board to the keypad flat cable connector as shown on the picture Place the protection plastic plate B with the adhesive tape as shown on the picture To protect...

Page 9: ...K R5 10 11 12 Connect the small adapter circuit board to the controller board Make sure the connectors are correct positioned and fully connected Place the adapter cable wires inside the con troller P...

Page 10: ...ct the system as shown in the system overview draw ing CONNECTING POS 11 14 TO POWER POS DESCRIPTION 1 12V 15 30 2 Ground 31 The power supply must be strong enough to operate the Sec tion and Master v...

Page 11: ...mber of sections and the width of each Refer to the CL230 user manual Wait for DGPS Green LED on Set the mode to AUTO Drive forward Min Speed 2 3 km h Observe that all sections and the master valve op...