CenterLine 230BP; Müller SPRAYDOS Installation Manual
020-041-UK R5
10
CenterLine 230BP; Müller SPRAYDOS Installation Manual
020-041-UK R5
10
+ -
1
1
2
2
1008-0189
15
/3
0
82
31
Be care full when the keypad is mounted in the
profile again. There is a risk for damaging the
flex board.
Assemble the controller again and connect the
system as shown in the system overview draw-
ing.
CONNECTING POS. 11 & 14 TO POWER:
POS
DESCRIPTION
1
+12V (15/30)
2
Ground (31)
The power supply must be strong enough to operate the Sec-
tion and Master valves. The total current will depend on the
used valve type.
BATTERY CABLE (OPTION):
If a power connector (Socket) isn't available in the tractor cabin, a optional battery cable can be
used (PN 96ET14).
! When connecting the system to 12V
power it's very important that the polarity
is correct, if not the system will be dam-
aged.