Wiring diagram
Note:
Must be hard wired, no plug allowed.
For your safe use in winter, it’s strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2
.
Options for protecting devices and cable specification
MODEL
INOA- R 6
INOA- R
8
INOA- R
12
INOA- R
14
INOA- R
18M
INOA- R
18T
INOA- R 24
Breaker
Rated Current
A
10.5
14.5
18.0
21.0
24.0
9.0
12.0
Rated Residual
Action Current
mA
30
30
30
30
30
30
30
Fuse A
10.5
14.5
18.0
21.0
24.0
9.0
12.0
Power Cord
(
mm
2
)
3×2.5
3×2.5
3×4
3×4
3×6
5x2.5
5x2.5
Signal cable
(
mm
2
)
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire diameter must be
increased. The signal cable can be extended to 50m at most.
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Supply
400V 50Hz
Breaker
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Supply
230V 50Hz
Breaker
B. For power supply: 400V 50Hz
Earthing
Earthing
Fuse
Fuse
Summary of Contents for INOA-R 12
Page 2: ......
Page 48: ...For installers and professionals 17 Appendix 1 Heating priority wiring diagram Optional...
Page 49: ...For installers and professionals 18 Appendix 2 Heating priority wiring diagram Optional...
Page 50: ...For installers and professionals 19 Appendix 3 Heating priority wiring diagram Optional...
Page 76: ...F r Monteure und H ndler 17 Anhang 1 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 77: ...F r Monteure und H ndler 18 Anhang 2 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 78: ...F r Monteure und H ndler 19 Anhang 3 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 115: ......
Page 116: ...Cc3I...