3. Technical specification
Model
INOA-R 6
INOA-R 8
INOA-R
12
INOA-R
14
INOA-R
18M
INOA-R
18T
INOA-R
24
Advised pool volume (m
3
)
20~40
30~55
40~75
50~95
65~120
65~120
90~160
Working air temp (℃)
-7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
8.4
12.8
17.3
20.4
27.3
27.0
35.6
C.O.P
14.1~7.0
15.0~7.4
14.8~5.9
14.5~5.7
14.6~6.2
14.5~6.2
14.6~5.5
C.O.P at 50% speed
10.3
11.0
10.5
10.2
10.8
10.8
10.3
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
6.1
8.3
11.4
14.0
18.0
18.0
24.0
C.O.P
7.0~4.8
7.7~4.8
7.5~4.3
7.4~4.2
7.8~4.6
7.6~4.5
7.7~4.5
C.O.P at 50% speed
6.3
6.8
6.1
6.1
6.5
6.5
6.8
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Cooling capacity (kW)
4.0
5.5
7.7
9.8
12.1
12.1
16.4
Rated input power(kW) at air 15°C
0.17~1.2
0.22~1.73
0.3~2.6
0.38~3.3
0.57~3.8
0.53~3.9
0.62~5.2
Rated input current(A) at air 15°C
0.74~5.2
0.96~7.52
1.3~11.3
1.65~14.3
2.48~16.5
0.76~5.6
0.89~7.4
Power supply
230V/1 Ph/50Hz
400V/3 Ph/50Hz
Advised water flux (m³/h)
2~4
4~6
6.5~8.5
8~10
10~12
10~12
12~18
Sound pressure 1m dB(A)
38.8~48.2
42.1~50.7
43.1~53.8
40.9~54.2
43.5~54.9
43.5~54.9
42.6~54.7
Sound pressure 10m dB(A)
18.8~28.2
22.1~30.7
23.1~33.8
20.9~34.2
23.5~34.9
23.5~34.9
22.6~34.7
Water pipe in-out Spec (mm)
50
Net Dimension LxWxH (mm)
961×340×
658
961×340×
658
961×420×
658
961×420×
758
1092×420×
958
1092×420×
958
1161×530×
958
Net Weight (kg)
45
50
63
68
90
93
120
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover,
filtration system running at least 15 hours a day.
Related parameters are subject to adjustment periodically for technical improvement without
further notice. For details please refer to nameplate.
Summary of Contents for INOA-R 12
Page 2: ......
Page 48: ...For installers and professionals 17 Appendix 1 Heating priority wiring diagram Optional...
Page 49: ...For installers and professionals 18 Appendix 2 Heating priority wiring diagram Optional...
Page 50: ...For installers and professionals 19 Appendix 3 Heating priority wiring diagram Optional...
Page 76: ...F r Monteure und H ndler 17 Anhang 1 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 77: ...F r Monteure und H ndler 18 Anhang 2 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 78: ...F r Monteure und H ndler 19 Anhang 3 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 115: ......
Page 116: ...Cc3I...