The purchased Product is covered by the manufacturer's or seller's warranty under the terms and conditions indicated in 
the  "Tecsystem  s.r.l.  General  Sales  Conditions",  which  can  be  consulted  on  the  website  www.tecsystem.it  and/or  in  the 
stipulated purchase contract. 
The  warranty  is considered  valid only  when  the  product is  damaged  by causes  attributable  to TECSYSTEM  srl, such  as 
manufacturing or components defects. 
The  warranty  is  invalid  if  the  Product  proves  to  have  been  tampered  with/modified  or  incorrectly  connected  and  causing 
voltages  outside  the  set  limits  and  does  not  comply  with  the  technical  data  for  use  and  assembly,  as  described  in  this 
instruction manual. 
The warranty is always ex Corsico as stated in the "General Conditions of Sale". 

  

  
 

The  European  directive  2012/19/EU  (WEEE)  has  been  approved  to  reduce  the  waste  of  electrical  and  electronic 
appliances  and  to  encourage  the  recycling  and  reuse  of  materials  and  components  of  these  appliances,  thereby 
reducing the disposal of harmful residues and compounds originating from electrical and electronic material. 
  

All the electrical and electronic equipment supplied after 13 August 2005 is marked with this symbol, pursuant to 
European  directive  2012/19/EU  on  electrical  and  electronic  waste  (WEEE).  Any  electrical  or  electronic 
equipment marked with this symbol must be disposed of separately from normal domestic waste. 

  
Returning  of  used  electrical  appliances:  contact  TECSYSTEM  or  the  TECSYSTEM  agent  to  receive  information  on 
correct disposal of the appliances. 
  
TECSYSTEM is aware of the impact its products have on the environment and asks its customers active support in the 
correct and environmentally-friendly disposal of its devices. 

  
 

EQUIPMENT DISPOSAL

 

TROUBLESHOOTING 

 

CAUSES AND SOLUTIONS

 

The  control  unit  does  not  switch  on  and  the 
supply to terminals 40-42 is correct. 

Check that: the connector is firmly inserted in its place, the connection 
wires  are  tight  and  that  there  are  no  obvious  signs  of  burns  on  the 
connectors.  Turn  off  the  power  supply  and  carry  out  the  above 
instructions, restore the voltage. 

CH4 is in FAULT (FOC) 

 

Programming  error  of  the  CH4  /  YES  control  unit.  Check  and  repeat 
the programming on page 19-20 select CH4 /NO. 

One of the three/four channels is in FAULT 
(FOC-FCC-FLT) 

 

Display  message 

FCC:

  exceeding  of  the  minimum  full  scale  value  = 

measured temperature < -35°C 
 
Display  message

  FOC

:  exceeding  of  the  maximum  full  scale  value  = 

detected temperature > 195°C 
 
Display message

 FLT

: Sensor disconnected or faulty. Check the state 

of operation of the FO sensors 

 

When turned on, the indication (ECH) appears 

A  strong  disturbance  has  damaged  the  memory  data.  See  the 
paragraph for programmed data diagnostics on page 18. 

The indication FAULT (TEC) is displayed 

CONC.521  is  disconnected,  it  is  advisable  to  check  the  connection 
between the CONC.521 and the control unit FO 935. 

 

Contact the TECSYSTEM Technical Department if the problem persists. 

 

WARRANTY REGULATIONS 

Summary of Contents for FO 935 ETH

Page 1: ...with ISO9001 certified quality system http www tecsystem it R 1 0 12 01 22 Translations of the original instructions ENGLISH TECSYSTEM S r l 20094 Corsico MI Tel 39 024581861 Fax 39 0248600783 FO 935...

Page 2: ...21 CFO 521 CONCENTRATOR OPERATION 13 6 FO 935 ETH ASSEMBLY 14 7 ELECTRICAL CONNECTIONS 15 FO 935 ETH BACK POWER SUPPLY 16 ALARMS AND VENTILATION FAULT AND RESET MESSAGE SEQUENCE CONC SENSOR DIAGNOSTIC...

Page 3: ...TES DATA TRANSMISSION NOTES ON ETHERNET ELECTRICAL CONNECTIONS FUNCTION CODE CODE 3 10 CODE 16 10 NOTES FOR REMOTE PROGRAMMING 22 ERROR CODES UNACCEPTABLE DATA ILLEGAL DATA 23 MODBUS MAPPING TABLE 11...

Page 4: ...y exceeding 90 and never touch with wet or damp hands If any liquid penetrates the control unit disconnect it immediately and contact technical assistance CLEANING Disconnect the power cable before cl...

Page 5: ...inal 4 pitch poles 3 81 connection CFO 521 Code 2PL0368 Screws tightening torque 0 25Nm CFO 521 Concentrator CFO 521 Concentrator Start guide and QR code 2 Terminals 4 pitch poles 3 81 connection FO 9...

Page 6: ...oards OUTPUTS 2 alarm relays ALARM AND TRIP SPDT 1 relay for faulty probes or operating anomaly FAULT SPST 2 ventilation management relays SPST FAN 1 and FAN 2 Output relays with 10A 250Vca res COS 1...

Page 7: ...s to display temperatures messages and channels 3 LEDs to display the state of the alarms of the selected channel ALARM TRIP FAULT 4 LEDS selection of display mode SCAN AUTO MAN T MAX 2 LEDs to displa...

Page 8: ...m 25 C to 60 C Permitted humidity 90 without condensate Degree of protection IP00 PC UL 94 HB container Electronic part protective treatment Optional DIMENSIONS 145x106 7x55mm CONC concentrator fixing...

Page 9: ...ication RS green LED 5 FAULT signalling red LED 16 3 digit channel display 6 FAN 1 yellow LED 17 T max mode selection red LED 7 FAN 2 yellow LED 18 Man mode selection yellow LED 8 Display mode selecti...

Page 10: ...ameters listed in the programming paragraph on pages 19 20 Return the control unit to TECSYSTEM for repairs 3 TEC err this message appears when a loss of communication is detected between the thermome...

Page 11: ...rature of the concentrator ranges from 25 C to 60 C therefore ensure there is adequate space between the concentrator and the transformer Maximum humidity 90 non condensing The CFO 521 support bracket...

Page 12: ...installed apply the protection bracket using the M4 screws supplied FO OPTICAL FIBRE TEMPERATURE SENSOR DIMENSIONS INSTALLATION READING POINT ST CONNECTOR CONNECTION OF THE CONC CFO 521 TO THE FO 935...

Page 13: ...etation of the measured values it is advisable to combine the CH2 probe with the central phase V The CFO 521 concentrator has a Pt100 input RTD class A 3 wire probe for the possible connection of a pr...

Page 14: ...1 Control unit 2 Panel hole dimensions 0 8 mm tolerance 3 Identification label 1 Control unit 3 Fixing screws 2 Fixing blocks 4 Cross head screwdriver 1X100mm FO 935 ASSEMBLY 1 2 3 4 1MN0008 REV 0 Dr...

Page 15: ...ntrol unit 1MN0257 REV 0 1 2 3 INDICATION AUDIBLE AND VISUAL ALARM CONDITION SYSTEM SHUTDOWN Note image relay contacts in non alarm condition except for the FAULT relay which switches contacts 10 11 c...

Page 16: ...the unit before performing any electrical connections eeprom fault concentrator communication bus fault min temperature full scale exceeded max temperature full scale exceeded broken or disconnected f...

Page 17: ...epairs TEMPERATURE DIAGNOSTICS When one of the sensors detects a temperature higher than 1 C with respect to the pre set value as the alarm limit after approximately 5 seconds the ALARM relay switches...

Page 18: ...5 7 Alarm and 8 10 Trip they switch only when the pre set temperature limits are reached or as a result of no voltage on the device FAULT By setting YES Fail safe contact 11 12 is positioned as norma...

Page 19: ...8 The display shows CH4 Enabling CH4 9 Select YES or NO with YES the CH4 is enabled with NO the CH4 is disabled 10 The ALARM threshold for CH4 appears and the Alarm LED flashes If CH4 NO jump to step...

Page 20: ...y TECSYSTEM might not match your requirements Programming the device is the end user s responsibility The settings of the alarm thresholds and enabling of the functions described in this manual must b...

Page 21: ...hose indicated in the paragraph notes for remote programming The ETH module is always in slave mode The FO 935 ETH control unit is in communication with the network only when it is in temperature read...

Page 22: ...and loads the new settings The information RELAY STATUS indicates the state of excitation of the coils of the relays so it will be subject to the commands of FAIL SAFE At the end of the write command...

Page 23: ...see table SYSTEM Setting and Status Value FCD max see table SYSTEM Setting and Status Value 4 20 max see table SYSTEM Setting and Status Voting Value max see table SYSTEM Setting and Status Note If t...

Page 24: ...FREE See Note R 12 00 00 FREE See Note R 13 00 CPU Setting See Notes RW 14 00 CPU Error See Notes R 15 00 Status Relay See Notes R 16 00 00 FREE See Note R 17 00 Address Modbus address 1 255 R 18 00...

Page 25: ...mpl sign 2 compl Ch1 temper 35 C 195 C R 26 2 compl sign 2 compl Ch1 max temperat 0 C 195 C R 27 2 compl sign 2 compl Ch1 temper alarm set point 1 C 190 C AL RW 28 2 compl sign 2 compl Ch1 temper trip...

Page 26: ...emper 35 C 195 C R 38 2 compl sign 2 compl Ch4 max temperat 0 C 195 C R 39 2 compl sign 2 compl Ch4 temper alarm set point 1 C 190 C AL RW 40 2 compl sign 2 compl Ch4 temper trip set point 1 C 190 C T...

Page 27: ...00 Ch4 Setting See Notes CHx RW 61 00 00 R 62 00 00 R 63 00 00 R 64 00 00 R CHANNELS 1 4 Status Address LO 10 Data HI Data LO Notes 1 Notes 2 W write W write W read write 65 Ch1 story Ch1 status See N...

Page 28: ...ATUS CHn STORY BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 TRIP ALARM FLT FOC FCC RELAY STATUS coil energising status BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FAULT Relay 1 ON TRIP Relay 1...

Page 29: ...et the Ethernet IP parameters 1 START menu Windows If already enabled the program appears 2 Start the search with the Telnet program Press ENTER to launch the program Entering telnet in SEARCH If inst...

Page 30: ...required 9 START menu Windows 10 Search for the Telnet program 15 Enter 192 168 10 120 9999 16 Press ENTER 12 TELNET SCREEN 11 Press ENTER to launch the program 13 Enter OPEN 14 Press ENTER 17 Enter...

Page 31: ...by the operator 2 Communication parameters between the ETH0 port and the control unit 3 Communication configuration between the ETH0 port and the control unit 4 Communication advanced settings between...

Page 32: ...2 Enter the desired new Gateway IP address press ENTER if you wish to keep the set address press ENTER 4 times At the end of the operation the system will ask if you wish to modify Netmask Type in Y t...

Page 33: ...e 27 4 Enter the new Telnet Password 4 digits max press ENTER if you wish to keep the set password press ENTER Type in S to save the modified data Q to exit Telnet without saving the data Indications...

Page 34: ...om normal domestic waste Returning of used electrical appliances contact TECSYSTEM or the TECSYSTEM agent to receive information on correct disposal of the appliances TECSYSTEM is aware of the impact...

Page 35: ...35 FO 935 ETH TECHNICAL INFORMATION ufficiotecnico tecsystem it COMMERCIAL INFORMATION info tecsystem it USEFUL CONTACTS...

Reviews: