Displaying LEDs 

 
The radiance or flashing of LED 1 (left) to LED 4 (right) has following meanings: 
 

LED meaning  

 

LED

‘s cyclical flashing impulse  

LED-1  (yellow) 

data from indicator.

 

 

۞  O  O  O 

 1 x 

1 flashing impulse (cyclical)  
     => Reception of a filling level telegram from the level indicator. 

LED-2  (yellow) 

sending status 
activity display

 

 O  

۞  O  O 

      1x 
 
 O  

۞  O  O 

      2x 
 
 O  

۞  O  O 

      3x 

1 flashing impulse (cyclical) 
     => Network dial-up and registration. Wait for max. 3min!  
  
2 flashing impulses (cyclical) 
     => SMS command is being received. 
 
3 flashing impulses (cyclical) 
    => SMS report is being sent by the GSM-Messenger 

LED-3  ( RED ) 
  
GSM Error 

 
 O  O  

۞

  O 

        

n times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

undefined 
blinking red

 

Error code GSM or modem: 
 

Red LED flashes n times?  This implies an ERROR: 

 
1 x  =  Internal modem does not respond. 

2 x  =  No SIM card detected inside the modem. 

3 x  =  PIN invalid (PUK entry necessary, therefore insert 
                               the SIM card into a mobile phone). 

4 x  =  Credit is empty. 

5 x  =  No / Bad reception (additional antenna?). 

6 x  =  SIM card is not registered / activated. 

7 x  =  Other modem error. 
           Registration was not successful, if necessary try to reset. 

8 x  =  Interlock active!

 

           In case of lots of failed network dial-up trials the device will 
           retry the dial-up only once a day. This mode operates for 
           255 days. By pushing the [Enter] button the device does 
           one logon trial to mobile network again. In case of success- 
           fully sending an SMS the interlock is removed. 

9 x =   No destination mobile number has been set up. 
           #T command has not been sent or OilView connection has  
           not yet been linked. 
 

Device is not sending.

 Probably internal interlock is active! 

1.

 Disconnect the power supply and switch in again. 

2.

 Query device via smartphone:  Send  #r  as SMS to the device 

    and wait for device replying (3 Min.). 

3.

 Trigger 1 SMS sending by pushing the Test button in the device. 

4.

 In error case check the SIM card with a smartphone. 

    Therefore send a SMS to the own mobile number. 

LED-4  (yellow) 

network reception

 

 O   O   O   

۞ 

                n x 

Flashes relative to the network reception. 
1 (very poor reception)  to  5 (very good reception). 

All LEDs on 

 

۞  ۞  

۞

  

۞ 

(permanently on) 

PIN entry request for the SIM card. To adjust the first PIN charac-
ter press the left button n times, then press OK (right). 
Accordingly repeat the process for the next 3 characters. 
With an 8-digit PIN, this must be deactivated with a mobile phone! 

Short flashing of 
all 4 LEDs 

 

۞  ۞  

۞

  

۞ 

(short flashing) 

Due to a problem with the modem communication the GSM-
Messenger performs an internal RESET and subsequently tries to 
redial into the mobile network. 

  

Summary of Contents for GSM-Messenger

Page 1: ...Content Page BASIC FUNCTIONS 2 COUNTING FUNCTIONS 2 SIM CARD 2 OILVIEW CONNECTION 2 ELECTRICAL INSTALLATION 4 DISPLAYING LEDS 6 DEVICE REPORTS 7 DEVICE PARAMETERIZATION 7 SMS REPORTS 7 TECHNICAL DATA...

Page 2: ...for a counter function For these counter functions potential free switching contacts are connected to input A1 or A2 These are typically either reed contacts relay outputs or make break contacts Via...

Page 3: ...ing contact possibly interpose a relay oil tank display 1 oil tank display 2 measuring probe tank 1 up to 100 m 2 wired control line GSM Messenger data transmitter mobile network with SIM card digital...

Page 4: ...ctivated Before connecting it to the 230V supply voltage check if the SIM card is inserted and engaged correctly into the designated modem Network connection Remove the mains fuse ensure safety Connec...

Page 5: ...Therefore press both buttons simultaneously and hold them for 5 sec During this process all registers and parameters will be reset Subsequently the PIN code of the SIM card needs to be reentered Afte...

Page 6: ...up trials the device will retry the dial up only once a day This mode operates for 255 days By pushing the Enter button the device does one logon trial to mobile network again In case of success fully...

Page 7: ...evice will also report the low levels at the beginning of a tank filling report text Info tank n Also via P7 1 Check Credit The credit of the SIM card has fallen below 1 Please recharge the credit Par...

Page 8: ...ory Order no 12068 Option A3 3 alarm input add on module IF 03 Option third alarm input A3 This device GSM Messenger A3 is equipped with an additional input module A make break contact is con nected t...

Reviews: