Tecson GSM-Messenger Installation Instructions And Technical Documentation Download Page 5

P. 5

 

Manual GSM-Messenger 

08-2019 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  

Insertion of the SIM card 

A SIM card (prepaid or contract) needs to be inserted into the GSM radio module. 
IMPORTANT: The SIM card has to be registered and activated. 
After the insertion of the SIM card the device requests to set the PIN code, see page 4. 

The sending fees for the SMS reports will be invoiced to the cardholder.  

’RESET’:   

In case of a device error a software reset possibly solves the error situation. 

 

 

Therefore shortly press both buttons.  

 

 

The adjusted parameters will remain unchanged. 

 
  
’RESET+Clear’ : 

The GSM-Messenger software can also be reset into the original delivery status. 

 

 

Therefore press both buttons simultaneously and hold them for 5 sec.

  

 

 

During this process all registers and parameters will be reset. 

 

 

Subsequently the 

PIN code

 of the SIM card needs to be 

reentered

 

 

After the modem reconnection the tank reregistration (tank order) possibly needs

 

 

to be carried out again. 

 

 

The commands #T and #H and all further commands need to be reset via SMS.

 

 

 

plus / test      OK button 

GSM module 

SIM 

card 

µP 

Status LEDs 

1

     

2

     

3

    

4

 

Inputs 

A1 | A2 

3 | 4  5 | 6 

Electronic 

oil tank indicator, e.g. 

Tankspion-Digital LX-2, 

for tank 1 

PC-Link input 

1 | 2 

7 | 8 

Input A3 

Contactor for alarm 

input A3  

(additional module, 

optional)  

Contactor for alarm 

input A1 resp.  

counter input 1 

PE   L   N 

Main supply 230 V~ 

Contactor for alarm 

input A2 resp.  

counter input 2 

 

Transformer 

If available: Further 

electronic oil tank 

indicators for tanks 

2,3,4 

Summary of Contents for GSM-Messenger

Page 1: ...Content Page BASIC FUNCTIONS 2 COUNTING FUNCTIONS 2 SIM CARD 2 OILVIEW CONNECTION 2 ELECTRICAL INSTALLATION 4 DISPLAYING LEDS 6 DEVICE REPORTS 7 DEVICE PARAMETERIZATION 7 SMS REPORTS 7 TECHNICAL DATA...

Page 2: ...for a counter function For these counter functions potential free switching contacts are connected to input A1 or A2 These are typically either reed contacts relay outputs or make break contacts Via...

Page 3: ...ing contact possibly interpose a relay oil tank display 1 oil tank display 2 measuring probe tank 1 up to 100 m 2 wired control line GSM Messenger data transmitter mobile network with SIM card digital...

Page 4: ...ctivated Before connecting it to the 230V supply voltage check if the SIM card is inserted and engaged correctly into the designated modem Network connection Remove the mains fuse ensure safety Connec...

Page 5: ...Therefore press both buttons simultaneously and hold them for 5 sec During this process all registers and parameters will be reset Subsequently the PIN code of the SIM card needs to be reentered Afte...

Page 6: ...up trials the device will retry the dial up only once a day This mode operates for 255 days By pushing the Enter button the device does one logon trial to mobile network again In case of success fully...

Page 7: ...evice will also report the low levels at the beginning of a tank filling report text Info tank n Also via P7 1 Check Credit The credit of the SIM card has fallen below 1 Please recharge the credit Par...

Page 8: ...ory Order no 12068 Option A3 3 alarm input add on module IF 03 Option third alarm input A3 This device GSM Messenger A3 is equipped with an additional input module A make break contact is con nected t...