![Tecson e-litro Start-Up & Operation Download Page 11](http://html1.mh-extra.com/html/tecson/e-litro/e-litro_start-up-and-operation_1072913011.webp)
V6.x // 06-2016
Setup and Operation
P. 11
Example 2
Buried tank, cylindric horizontal, for 10,000 liters diesel,
Inner height 1.59 m, (filling level 54 cm), LITRO-level probe 0 -
250 mbar
Device
e-litro gsm
with SIM card:
Menu item
1. Measuring probe
2. Liquid
3. Tank shape
4. Tank volume
5. Tank height
5b. Filling limit
6. Display
7. Relay
8. ( Exit )
. . .
15. Modem
. . .
19. Exit [Enter]
Setting / Selection
250 mbar
Diesel oil
Cylindric horizontal
10050 l (exact value from bearing chart)
159.0 cm (exact value from bearing chart)
99% (no limit indicator)
Fil Level
On: 96% Off: 94% (relay energizes at 96%)
Go forward to next step with [+]
...
PIN: xxxx - enter the PIN code of the SIM-card
...
Displaying mode => ... 1280 l ... 13 %
Example 3
e-litro secu4
device with 4 battery tanks 4 x 1250 liters,
steel tanks with hemicycles at top and bottom, 155cm tank height,
display: Fillspace + Level for each single tank
disable tank filling at a limit of 94%.
Menu item
1. Number of tanks
2. Liquid
3. Tank shape
4. Tank volume
5. Tank height
5b. Filling limit
6. Display
7. Unit
8. Exit [Enter]
Setting / Selection
4
Heating oil
Steel tanks
1250 L (x 4)
155.0 cm
94% = 146cm
Not available for secu4 (no function)
Active =>
‘on’ at 99% ; ‘off’ at 10% of the filling level
Back to displaying mode;
Display 1 (details per tank) switches with
Display 2 total inventory in L; filling space in L
Tank with interior mantle
In case of a tank with interior mantle (e.g. horz. cyl. or cellar steel tank) correct the input values.
Example: Mantle thickness: ca. 5
– 10 mm:
=> Enter
‘5.Tank height’:
reduce height by ca. 15 mm
=> Enter
‘4.Tank volume’:
reduce volume by ca. 2 %