P. 8
Tecshow Quadbar 16 IP |
Restore factory set
After carry out this function, all data will restore
initial state. Please press the setup button to enter
and select by the up or down button. As followings:
Language selection
Please press the setup button to enter and select
by the up or down button. As followings:
Information mode
Save related messages.
RDM (Remote Device Management)
This product supports RDM communication proto
-
col. RDM is a protocol that supports two-way traffic
in the standard DMX512 protocol. RDM control
devices, configurations and detect lights. Such
as changing the DMX address of the fixture, DMX
mode, and so on. Each RDM - compatiblelight can
be identified by the built-in unique UID code.
English version
Factory
Yes
No
Language
English
Chinese
Information
Versions: x.x.x
Temperature: xx°C
UID:xxxxxxxxxxxx
Parameter ID
Discovery command
SET command
Get command
DISC_UNIQUE_BRANCH
*
DISC_MUTE
*
DISC_UN_MUTE
*
DEVICE_INFO
*
SOFTWARE_VERSION_LABEL
*
DMX_START_ADDRESS
*
*
IDENTIFY_DEVICE
*
*
SUPPORTED_PARAMETERS
*
SENSOR_DEFINITION
*
SENSOR_VALUE
*
DMX_PERSONALITY
*
*
DMX_PERSONALITY_DESCRIPTION
*