15
HYDROPONIC
C
H
I
L
L
E
R
L
I
N
E
EN
, make sure that the water fl ows regularly in the circuit and that there are no
leaks. In the case of anomalies or leakage in the hydraulic circuit, review the
connections.
11)
CAUTION: Make sure that the water that reaches the device is fi ltered.
12) Make sure that the power supply requirements match those shown on the tech-
nical plate, visible on the back of the unit (Ref. A3 Fig. 4).
13) When the aquarium pump is functioning, connect the cable power supply to the
power socket with the plug. Then, the display will show OFF.
Pressing the power button (Ref. A7 Fig. 14) for at least 3 seconds, your device
will start working, on the display it is indicated the actual water temperature. To
display the temperature to be reached press the SET button (Ref.A8 Fig.14) to
return to the water temperature press the SET button (Ref.A8 Fig.14) or wait for
5 seconds.
14)
CAUTION: A 2-minutes delay was added to prevent compressor failure
at the fi rst start.
15) To stop the device, press the power button (Ref. A7 Fig. 14) for at least 3 sec-
onds, the display will show OFF.
CAUTION: The appliance must be installed at a height below the water
level.
CAUTION: To prevent damages, the unit cannot operate without water
fl ow (pump off ).
CAUTION: Connect only the TECOnnect Wi-Fi module (not supplied) to
connector (Ref. A4 Fig. 4). Do not connect any other device to this con-
nector in order not to damage the chiller thermostat.