12.
Vibration gauge installation position (recommended)
Vibration measurement must observe the following rules according to ISO-10816
standard.
1. Close to the bearing
2. In direction either vertical or horizontal rather than 45-degrees or tilted
direction
3. See diagram below for recommended installation position where the arrow
symbol indicates direction and letter "x" the installation position.
Vibration gauge 3-axis direction
Vertical
Vertical
Horizontal
Axial
Axial
Axial
Vertical
Vertical
Axial
3 Axials X/Y/Z Position
3 Axials X/Y/Z Installation Location
安裝位置圖
Horizontal
Horizontal
Horizontal
VB-200STU
Direction
identification
Direction
identification
Direction
identification
Direction
identification
Direction
identification
Direction
identification
Direction
identification
Direction