TECO TECOMAT FOXTROT IB-1301 Basic Documentation Download Page 14

Basic documentation for IB-1301 module

6.

OPERATION

6.1

MODULE CONFIGURATION

The module is operated, set and diagnosed from the MOSAIC development environment.

6.2

PUTTING IN OPERATION

After connection and switching power supply on, the module is ready for its activity.  On the

module panel there is set a module address within the system. Other parameters are set from
the Mosaic development environment. The detailed set-up procedure is described in document-
ation TXV 004 10. Other activities are carried out in the MOSAIC development environment.

7.

DIAGNOSTICS

The basic diagnostic system of the module is a part of the standard module software. The

diagnostic system becomes active after module power supply is on, and works independently
from the user. The error states being diagnosed are described in documentation TXV 004 10.

8.

MAINTENANCE

When following general installation instructions are kept, the module does not require any

other   maintenance.   Should   dismantling   of   some   part   of   the   module   be   necessary,   supply
voltage must always be OFF. 

Since the module contains semiconductor components, it is necessary to
follow the principles for working with components sensitive to electrostatic
charges when handling the cover taken off. It is strictly prohibited to touch
printed circuits directly without protective measures!!!

9.

GUARANTEE

The guarantee and complaint conditions are governed by the Business conditions of Teco a.s.

Attention:
Before switching the system on, you must fulfil all the conditions contained in this documenta-

tion. The system must not be put in operation, if it is not verified and confirmed that the equip-
ment   in   which   the   Foxtrot   system   is   part   of   it,   meets   the   requirements   of   the   directive
89/392/CEE, if the directive applies to such equipment.

We reserve the right to make modifications and/or changes of the documentation without pri-

or notice.

TXV 113 01

14

Summary of Contents for TECOMAT FOXTROT IB-1301

Page 1: ...2011 3rd edition March 2011 Podrobn u ivatelsk dokumentace je k dispozici na firemn m CD INFO a na www tecomat cz pod n zvem Programovateln automaty TECOMAT FOXTROT obj slo TXV 004 10 Detailed user d...

Page 2: ......

Page 3: ...n Nap jec nap t typ 24 V DC Intern ji t n Ne Typick p kon 1 W Maxim ln p kon 2 W Galvanick odd len nap jen od vnit n ch obvod Ne Kryt SN EN 60529 1993 idt IEC 529 1989 IP10B Hmotnost 105 g Rozm ry 90...

Page 4: ...ick odd len od vnit n ch obvod Ano Diagnostika signalizace vybuzen ho vstupu LED na panelu modulu Spole n vodi minus plus Vstupn nap t pro log 0 UL max 5 V DC min 5 V DC pro log 1 UH min 15 V DC typ 2...

Page 5: ...CLR DI3 CAP ta s zen m sm ru s nulov n m a zachycen m DI0 CLK DI1 DIR DI2 CLR DI3 CAP IRC s nulov n m a zachycen m DI0 V DI1 G DI2 NI DI3 MD M en d lky pulzu za chodu voliteln vstup DI0 DI3 M en perio...

Page 6: ...zsahu zak zky a zp sobu p epravy do p epravn ho obalu opat en ho p epravn mi etiketami a ostatn mi daji nutn mi pro p epravu P eprava od v robce se prov d zp sobem dohodnut m p i objedn v n P eprava v...

Page 7: ...en modulu IB 1301 7 TXV 113 01 COM2 DI4 DI5 DI6 DI7 DI8 DI9 DI10 DI11 TCL2 TCL2 GND 24V COM1 DI0 DI1 DI2 DI3 TC LINE 24 V DC DIGITAL INPUTS DIGITAL INPUTS IB 1301 ADR 0 1 2 3 4 5 6 7 8 9 RUN BLK 24 V...

Page 8: ...V 004 10 8 DR BA P i dodr en v eobecn ch podm nek pro instalaci nevy aduje modul dnou dr bu kony p i kter ch je t eba prov st demont n kter sti modulu se prov d j v dy p i odpojen m nap jec m nap t Pr...

Page 9: ...solation from internal circuits No Coverage SN EN 60529 1993 idt IEC 529 1989 IP10B Height 105 g Dimensions 90 53 65 mm 1 2 OPERATIONAL CONDITIONS Class of ambient influence SN 33 2000 3 1995 mod IEC...

Page 10: ...s Diagnostics indication of energized input by LED on module panel Common pole for the group minus plus Input voltage for log 0 UL max 5 V DC min 5 V DC for log 1 UH min 15 V DC typ 24 V DC max 30 V D...

Page 11: ...pturing DI0 CLK DI1 DIR DI2 CLR DI3 CAP Incremental encoder with reset and capturing DI0 V DI1 G DI2 NI DI3 MD Measuring pulse length input DI0 DI3 selectable during operation Measuring period and shi...

Page 12: ...containing all the necessary data for transportation The goods is transported from the manufacture s facilities as agreed when placing an order Transportation of the goods by the customer must be purs...

Page 13: ...ection of IB 1301 module 13 TXV 113 01 COM2 DI4 DI5 DI6 DI7 DI8 DI9 DI10 DI11 TCL2 TCL2 GND 24V COM1 DI0 DI1 DI2 DI3 TC LINE 24 V DC DIGITAL INPUTS DIGITAL INPUTS IB 1301 ADR 0 1 2 3 4 5 6 7 8 9 RUN B...

Page 14: ...hen following general installation instructions are kept the module does not require any other maintenance Should dismantling of some part of the module be necessary supply voltage must always be OFF...

Page 15: ...Notes...

Page 16: ...Teco a s Havl kova 260 280 58 Kol n IV Czech Republic URL www tecomat cz e mail teco tecomat cz...

Reviews: